Caution!
Use an open-ended wrench to hold the water quantity regulators (d) in position while
turning the cap nuts (c).
11.6 Remove the T-type flush connector (e) and any seals that are present.
11.7 Install the function block (f) and the connection extension (g) with new seals.
11.8 Use an open-ended wrench to fasten the connection piece (h) until it seals to G½B level.
11.9 Slide the wall bracket (k) onto the connection piece (h).
11.10 Fasten the grub screw (i), using an Allen key.
11.11 Open the water volume regulators (see
11.12 Check the water connections for leaks.
11.13 Release the screw (n) with its disk.
11.14 Remove the temperature selector (m) and the stop ring (l).
11.15 Pull the protective foil off the cover plate.
11.16 Seal the cover plate, e.g. with Chromol (not part of the delivery scope, see Acces-
sories
Chapter
11.17 Connect the wires between the electronic module, the solenoid valve cartridge and
the optical sensor.
A: Solenoid valve cartridge for mixed water
B: Solenoid valve cartridge for thermal disinfection bypass (optional)
C:Cold water temperature sensor (optional)
D:Hot-water temperature sensor (optional)
E: Optical sensor
F: Electrical T-distributor system cable (power)
G:Electronic module
11.18 Fix the cover plate (r), using the safety screws (o).
11.19 Remove the locknuts (p).
11.20 Push on the rosette (s).
11.21 Push the headpiece (u) onto the wall bracket.
11.22 Fasten the grub screw (v), using an Allen key.
11.23 Fit the rosette (t) in such a way that the markings are at the top.
11.24 Turn the adjustment nut (w) so that the two markings (x) are aligned.
☞
The maximum water temperature has been set to 38°C
11.25 If necessary, set the scald protection to another temperature (see
11.26 Mount the stop ring (l) in such a way that the marking (z) is centred below the stop
ring, centrally below the markings (y) for the rosette.
☞
Important!
Mount the temperature selector (m) in such a way that the stop is flush against the
stop ring crosspiece.
11.27 Push the temperature selector (m) onto the stop ring (l).
11.28 Attach the temperature selector (m) and its screw and disk to the fitting.
11.29 Fit the cover platelet (n).
11.30 Check the range and adjust where necessary (see
26).