KAIROS
Quick Installation Guide
This Quick Installation Guide is a summary of the complete installation manual. This manual contains safety
and other explanations which must be precaution You can download this Quick Installation Guide in the
Advise
"Download" section of the website of Erreka:
http://www.erreka-automation.com
G
D
C
Electrical Wiring
A.B: 24v DC Motor(2x1mm²)
C: Photocell 2x0.5mm² (max 20m)
D: Control Box (3x1.5mm²)
E: Push Botton 2x0.5mm²(max 25m)
KAIROS It is not applicable to an insecure or lacking rigidity door nor solves the defects due to incorrect installation or
maintenance de cient.
Check the following points before starting the installation:
1). Hinges are properly positioned and greased.
2). No obstacles in the moving area and no frictions between two gate leafs or with the ground while moving.
3). "C" value is 139mm.
4). "D" can be measured from the gate easily.
5). "A" = "C" + "D"
6). The value of "B" can be calculated from the value of "A" and the leaves opening angle.
Ex. If "A"=160mm with the leaves opening angle of 100 degrees, then the value of "B" is approximate 190mm.
B
D
A
C
Elements of the complete installation
Elementos de la instalación completa
A
TA
F: Key Selector(2x0.5 mm²)
G: Flash Light (2x0.5mm²)
H.I: Electronic Latch (2x1mm²)
Dimensions and mounting position
Please make sure B and A are similar or the same in value that the leaves can be
operated smoothly, also to reduce the burden of the motor.
H
TC
I
A
110
120
130
140
150
160
170
180
E
0
B
TA
TA: Open Doorstop
TC: Closed Doorstop
B
110
120 130 140 150 160
170 180
>120°
110°~120°
100°~110°
90°~100°
Open Interior
MSB-027/01
F
1 1