Piping
The pipework should be installed using standard tools and connected in such a way that there is no AIR leaking from the
connections. Any malfunction and leakage in the system can also be avoided with an installation that is properly adjusted
taking into account the possible movements and loosening of the connections for varied reasons.
1) The pipes should be assembled in accordance with the
direction of circulation of the compressed air after
inspection of the inlet and outlet of the AIR DRYER.
(Assembling the pipes in the wrong direction causes the
AIR DRYER to malfunction).
2) The pipes should not rest directly on the AIR DRYER but
on a support so that they are isolated from the device.
3) Condensed water coming in from the outlet of the drain
device should be evacuated through a separate pipe.
4) The AIR DRYER should be isolated from the vibrations of
the AIR COMPRESSOR.
5) It is recommended to install a bypass line in order to
facilitate repairing the AIR DRYER (use connecting pipes).
6) It is also recommended to use non-corrosive piping for
better corrosion resistance.