The Drummotor does not run
The Drummotor overheats
The Drummotor makes a humming sound, it runs, but extremely slow or does not run at all
The Drummotors overloads have „tripped"
The Drummotor makes a lot of noise
Remark:
If you cannot solve the problem, please contact your nearest Van der Graaf distributor.

Trouble-shooting

1
Check all connections.
2
Check the power supply.
3
If it is a three-phase drum motor, check the voltage
between all three phases. This must be equal.
1
Ensure that the ambiant airtemparature does not
exceed 40°C.
2
Avoid electric overload.
3
Check FLC with a clamp ammeter, the current
consumption should not exceed the FLC value
indicated on the data plate.
4
Check the conveyor for belt slip.
1
If it is a three-phase Drummotor, check the voltage
between all three phases. This must be equal. Also
check for possible interruptions in the winding.
2
If it is a single-phase Drummotor, the start capacitor(s)
is/are to be checked as well as the start switch. Check
for possible interruptions in the winding.
1
Check for a short circuit.
2
If a short circuit is not present, reactivate the power
and check the FLC using a clamp ammeter.
1
Is the Drummotor correctly mounted (page 26)?
2
Check whether the indented arrow on the mounting
shaft opposite the junctioin box end points upwards.
3
Check if the tension of the conveyor belt is not too
high.
1
Ensure correct electrical connection of the brake
Drummotor.
2
Check the supply voltage of the Drummotor and of
the brake.