CONTROL PANEL

FUNCTION PADS
COOL DOWN
PAD
MenuKey 2
The MenuKey System automatically changes all the
cooking programs with an electronic key and allows
program names to be identified
COOL DOWN PAD
Puts the oven into Cool Down Mode, see Cleaning 
page 9.
CANCEL PAD
Cancels all timed cooking cycles, pre-programmed
operations and stops the microwave energy. it does not
alter the oven temperature. if the oven is hot, food will
continue to cook and should be removed from the oven
immediately. This pad will also cancel any incorrect
operations. it will not erase programs.
Display Panel error messages
Message
eRROR MAGneTROn 1
eRROR MAGneTROn 2
eRROR MAGneTROn 1 & 2
CAVITY SENSOR ERROR
DISPLAY PANEL
CATeGORieS
CAT 00
CAT 00
CAT 003
CAT 004
FUNCTION PADS
Condition
Magnetron  has overheated
Magnetron  has overheated
Magnetron  and  have
overheated
Cavity temperature exceeds
more than 50°C above
PReHeAT temperature
setting during cook cycle
FUNCTION PADS
CAT 005
CAT 006
CAT 007
CAT 008
DISPLAY PANEL
Shows the principal functions of the oven.
When cooking, the time remaining counts down.
Also displays error messages and oven temperature.
When storing and recalling a program the display
indicates the program number and details.
FUNCTION PADS
The function pads select options shown in the DISPLAY
PANEL.
Possible cause
Blocked Air filter(s)
Oven located near hot air sources
Oven being used empty
- Call Service Engineer
indicates combustion ( fire ) in oven cavity