Fostoria FES and YES series heaters are designed
to circulate room air across its heating elements to
gradually increase room temperature. The best
performance results will be obtained when using
these heaters in smaller, confined spaces with low
ceilings.
Operation of these heaters is accomplished via the
use of a multi-function thermostat (refer to
diagram below).
LOW
HEAT
You have the option to use the fan only*, or the
fan and heating elements together. Position the
knob pointer in the "fan-only" area to circulate
room air with no heating. Move the pointer into
the "heat" area to energize the heating elements
and set the thermostat. Maximum heating is
obtained with knob turned fully clockwise**.
Both fan and elements are off when the knob is
turned fully counterclockwise.
Allow the fan to operate for a minimum of 3
minutes when you are done using the heater to
purge heat from unit.
*The thermostat has a preset range of 40˚F to
100˚F.
If the ambient room temperature is
below 40˚F, there will be no "fan only"
function as the thermostat is always calling for
heat.
**Setting the thermostat to high heat versus
low heat does not make the unit operate at a
higher temperature.
temperature
necessary
thermostat. The unit will run longer to try to
satisfy a higher thermostat setting.
Issue Date: 4-19-02 Rev. Date: 12-21-05 Rev. Level: 12
OPERATING INSTRUCTIONS
HIGH
HEAT
HEATER
OFF
It simply raises the
to
satisfy
Note: ALL FES/YES models are equipped with
an internal over temperature limit designed to
protect your heater if a restricted airflow
condition
completely shutdown the heating elements if the
temperature limit is reached. The limit will
automatically reset when the unit cools.
• Do not use outdoors or where
flammable gases or liquids are stored.
• Do not use as a residential comfort
heater.
• Keep portable heater 3ft. minimum
from all combustible materials at all
times.
• Do not modify heater in any way.
• Do not provide power to heater when
unit is near standing water.
• Only use handle to move heater.
• Do not touch heater housing while in
use.
• Do not allow feeder cable to contact
combustible materials.
• Always purge heat from unit after
use. Operate at "fan only" setting for
the
3 minutes.
OIPM P/N 3420458
occurs.
This
limit
FIRE HAZARD
EXPLOSION HAZARD
BURN HAZARD
• Serious injury or death
may occur.
• Read and follow all safety
information in box below.