Advanced Functions - Fantini Cosmi C58 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

O P E R A T I N G
working HOURS
since last
initialisation
P R E V I O U S D A Y M I N I M U M A N D M A X I M U M
T E M P E R A T U R E S
TIME when the
temperature was
recorded MAXIMUM or MINIMUM
S U M M E R / A I R - C O N D I T I O N I N G M O D E
Intellitherm C58 starts the AIR-CONDITIONING mode moving the switch to the SUMMER
position
The red sectors on the ring indicate what time the air-conditioning is ON; the other colours
indicate when the system is OFF
T E C H N I C A L
F E A T U R E S
In compliance with CEI EN 60730-1 and parts two
Contact rating 5 (3)A 250V c.a.
Micro-disconnection (1BU)
Software classe A
Voltage free switching contact
Temperature regulation: COMFORT from 2° to 62°C;
ECONOMY from 2° to 62°C
Differential: +/- 0,25°C
Thermal gradient: 4°K/h
OFF mode with optional antifreeze protection (5°C) by a dip switch.
Maximum room temperature: T45.
double insulation
Protection degree IP20
9
H O U R S
A1 A2
working HOURS
on the day before
A1 A2
room temperatures
. The COMFORT/TMAX temperature can be regulated pressing the red keys.
With C58 it is possible to know for how many hours the heating
system worked the day before (closed relay – ON) and from the
last Intellitherm initialization (last reset or battery insertion).
The display will show the heating working hours, positioning
the switches as indicated in the picture.
With Intellitherm C58 it is possible to verify the MINIMUM and
MAXIMUM temperatures reached the day before and what time
they were measured.
Move the switch to the ECONOMY position
MINIMUM temperature or move to the COMFORT position
to read the MAXIMUM temperature.
Move the switch to PROG
Pollution degree 2
Impulse voltage 4000V
Power supply without connection to the electrical line with
2 AA 1,5V alkaline batteries (1 year battery life).
Automatic control of the battery charge; the display will
indicate if the charge is inadequate.
Battery replacement without data dropout.
Switch for the winter or summer operating modes.
Reset key to restore the set program.
Dimensions 130 x 80 x 17 mm
ErP classification: ErP Class IV; 2% (EU Reg. 811/2013
- 813/2013)