INSTALLATION
STEP
7
Install
the Door Control
Locate the door control within sight of the door at a
minimum height of 5 feet where small children cannot
reach, and away from all moving parts of the door and
door hardware.
1. Strip 7/16" (11 mm) of insulation from one end of
the bell wire. Connect it to the two screw terminals
on the back of the door control by color: white wire
to 2 and white/red wire to 1.
2. Fasten the Lighted Door Control Button securely
with 6ABx1-1/2" screws. If installing into drywall,
drill 5/32" holes and use the anchors provided.
3. Run the bell wire up the walt and across the ceiling
to the opener. Use insulated staples to secure the
wire in several places. Be careful not to pierce the
wire with a staple, creating a short or open circuit.
4. Receiver quick-connect
terminals and the antenna
are located on the back panel of the motor unit.
Position the antenna wire as shown.
5. Strip 7/16" (11 mm) of insulation from end of bell
wire. Connect bell wire to the quick-connect
terminals as follows: white to white and white/red to
red.
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.
6. Use tacks or staples to permanently attach the
entrapment warning label to the wall near the door
control, and the manual release/safety reverse test
in a prominent location on the inside of the
garage door.
NOTE: DO NOT connect the power and operate the
opener at this time. The trolley will travel to the full
open position, but will not return to the close position
until the sensor beam is connected and properly
aligned. See Safety Reversing Sensor instructions
beginning on page 21.
To prevent possible SERIOUSINJURYor DEATHfrom
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLYto 24 VOLTlow voltage wires.
To prevent possible SERIOUSINJURYor DEATHfrom a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet, and
away from all moving parts of door.
• NEVERpermit children to operate or play with door
control push buttons or remote control transmitters.
• Activatedoor ONLYwhen it can be seenclearly,is properly
adjusted,and there are no obstructionsto door travel.
• ALWAYSkeep garage door in sight until completely
closed. NEVERpermit anyone to cross path of closing
garage door.
Hardware Shown Actual Size
6ABx1 _t/2" Screw
insulated
Lighted Door Control Button
Dry Wall Anchors
Staples
a(O
Bell Wire
Lighted Door
Control Button
Terminal Screws
i
Lighted
Door Control Button
Wiring to Terminal Block
Strip 7/16" (11 ram) of insulation from each wire.
insert wires through opening on top of motor
unit above terminal block, then into quick*
connect terminals.
Door Control
Connections
Strip wire 7/16" (11ram)
To release wire, push in tab
with screwddver_tip
_¥
Red White
Grey
21