Idiomas disponibles

Air gaps (switching distance) (mm) for safe switching
function (correct operation of the elobau control unit):
ON
Magnet
N
 4
671271
 4
671261
 4
671262
671V62
(N)
normal magnet
(S)
strong magnet
(MIN.) minimum air gap
(*)
enables a system restart
Note Only use strong type magnets when an operating gap of
more than 4 mm is required.
When choosing and installing the magnets:
 Observe maximum allowable opening of the guard.
20.12.2018
OFF
S
N
S
 7
 11
 17
 7
 14
 20
 7
 16
 20
MIN.
N
S
N
 0.5
 3
 16
 0.5
 3
 0.5
 3
ENG
OFF *
S
 23
39/136