CHECKING
Check the operation according to the chart below.
Power OFF
Entry motion
(image)
Sensor status
Operation indicator
Output
Note
The door may open once after the power is switched on.
Inform the following items to the building
owner/operator
1. When turning the power on, always walk-test the sensor pattern to ensure proper operation.
2. Always keep the detection window clean. If dirty, wipe the window with a damp cloth. (Do not use any cleaner or solvent.)
3. Do not wash the sensor with water.
4. Do not disassemble, rebuild or repair the sensor yourself; otherwise electric shock may occur.
5. Contact your installer or the sales engineer if you want to change the settings.
6. Do not place an object that moves or emits light in the detection area. (Ex. Plant, illumination, etc.)
7. Do not paint the Detection Window.
TROUBLESHOOTING
TROUBLE
Power supply is not adequate.
NE DOES NOT
OPERATE
Connection Failure.
Dirty detection window.
DOSE NOT OPERATE
CONSISTENTLY
Sensitivity is Low.
There is an object that moves or emits light in the detection area.
(Ex. plant, illumination, etc.)
Vibration of the header.
Sensitivity is high.
Waterdrops on detection window.
OPERATES BY ITSELF
Detection area has interfered the area of another sensor.
(GHOSTING)
The detection 1st row spots are overlapping with the door / header.
There is an refl ected object in the detection area. Solar light
refl ects.
There was a puddle left by rain or snow. The fl oor has gotten wet.
The exhaust of the car and the fog penetrate into the detection
area.
DOOR STAY OPEN OR
Presence timer is Infi nity. There was an abrupt condition change in
CLOSED
the detection area.
DECLARATION CE OF CONFORMITY
Pursuant to the Electromagnetic
compatibility Directive
CAME CANCELLI AUTOMATICI S.p.A.
Via Martiri della Libertà, 15
31030 Dosson di Casier
TREVISO - ITALY
All data checked with the maximum care. However, no liability is accepted for any error or omission.
The declaration de conformity and other technical documentation are available on our website www.came.it -
CAME
CANCELLI AUTOMATICI S.P.A.
V
M
D
IA
ARTIRI
ELLA
31030 D
OSSON DI
Treviso - ITALY
(+39) 0422 4940
(+39) 0422 4941
Outside the
Detection area
Stand-by
Power OFF
OFF
Green
Yellow
Yellow
Green
Green
White
White
POSSIBLE CAUSE
Contact your installer or the sales engineer if:
- the trouble still persists after checking and remedying as described above.
Is fully liable in declaring that the
products listed below:
MR8003
comply with the National Law related
to the following European Directives
and to the applicable parts of the
following Standards:
A
T
SSISTENZA
ECNICA
N
V
UMERO
ERDE
L
, 15
800 295830
IBERTÀ
C
ASIER
W
EB
www.came.it
E-
MAIL
Entry into 3rd or
Entry into 2nd Row Entry into 1st
4th Row
Motion
Motion or Presence
Detection Active
Detection Active
Orange
Yellow
Green
White
Adjust to stated voltage.
Check the wiring and the connector.
Wipe the detection window with a damp cloth. (Do not use any
cleaner or solvent.)
Set the Sensitivity Switch "H."
Remove the object.
Secure the header. Or set the Sensitivity Switch "L."
Set the Sensitivity Switch "L."
Install in a place keeping the waterdrops o . OR use a rain-cover
(Optional).
Set the di erent frequency position each other.
Adjust the detection area to deep (outside).
Remove the object.
This sensor is equipped with the anti-malfunction. However, pay
attention when installing as malfunction may occur under the left
conditions.
Turn the power o and on again.
2014/30/UE
Electromagnetic compatibility Directive
2006/95/CE
Construction products Directive
-----
EN 13241-1 / EN 61000-6-2 / EN 61000-6-3
EN 300 330-2 / EN 300 440 / EN 300 440-2
EN 300 683 / EN 301 489-1 / EN 301 489-3
BUY-TO-SELL PRODUCT
Outside the
Row
Detection area
Stand-by
Red
Green
Yellow
Green
White
SOLUTION
EN 50081-1 / EN 50081-2 / EN 50392
EN 60335-1 / EN 60335-2-103
EN 60950 / EN 60950-1
The Managing Director
Gianni Michielan
Reference code to
DDC E EN
request a true copy
of the original
R001