Preliminary Warnings; Technical Specifications - Seneca Z Serie Manual De Instrucciones

Módulo conversor universal con 2 salidas analógicas separadas galvánicamente
Ocultar thumbs Ver también para Z Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

2. PRELIMINARY WARNINGS

Before carrying out any operation it's mandatory to read all the content of this user
Manual . Only electrical-skilled technicians can use the module described in this user
Manual.
Only the M
components.
No warranty is guaranteed in connection with faults resulting from improper use, from
modifications or repairs carried out by
module, or if the content of this user Manual is not followed.
3. DESCRIPTION AND CHARACTERISTICS
3.1 MODULE DESCRIPTION
The Z170REG module acquires 1 universal input signal and converts it to an analog format,
sent through 2 universal output signals (regardless and isolated with each other).
3.2 GENERAL CHARACTERISTICS AND FEATURES
- It's possible to choose if the input is: voltage type, current type, potentiometer type,
thermocouple (TC) type, RTD (Resistance Temperature Detector) type.
- It's possible to choose if each output is: voltage type, active/passive current type.
- 1500 V insulation between: input, power supply, output 1 and output 2 (figure 1).
~
- It's possible to power the sensor if input is in current type modality (max17V).
- It's possible to configure by Dip-Switch or by software (available at www.seneca.it)
modality: input-type, outputs-type, start / end scale of each selected input and outputs-type
- It's possible to configure by software: input filter, rejection, burn-out, etc..

4. TECHNICAL SPECIFICATIONS

4.1 INPUTS
Number
Resolution
Sampling time
Filter
Response time
Voltage-type
Input (1)
Current-type
Input (passive
module / active
module) (1)
Potentiometer
type Input (1)
Thermocouple
type Input (1)
RTD-type
Input (1)
anufacturer is authorized to
1
14 bits
Configurable between: 16.66 ms (rejection to 60 Hz) or 20 ms (rejection to 50 Hz)
Level configurable between: 0(no filter is applied) – 19
Sampling time +6 ms
Scale span configurable: from 0 to 10V
Input automatic out of range detection.
Scale span configurable: from 0 mA to 20 mA. Internal shunt: 50
power the sensor by: itself (passive module) or by module (active module using #7
screw terminal, max 25 mA to max 17 V, short-circuit protected).
Input automatic out of range detection.
Scale span configurable: from 1 % to 100 %.
Potentiometer input value from 1 k to 100 k (a R= 330
added). Energising current: 1 mA. Input impedance: > 5 MW.
Input automatic out of range detection.
For TC type: J, K, R, S, T, B, E, N. Input impedance: > 5 MW.
Input automatic burn-out detection.
F o r RT D t y p e : P
(for 2,3,4-wires connection) and wire-resistance measure. Excitation current: 1.1 mA
(PT100) and 0.11 mA (PT1000, PT500). Input automatic burn-out detection.
repair the module or to replace damaged
M
anufacturer-unauthorised personnel on the
~
W
T
1
0 0 , P 5 0 0 , P 1 0 0 0 , N 1 0 0 . R e s i s t a n c e m e a s u r e
T
T
MI002282-E
. Input impedance:120 k
parallel circuit must be
W
W
I
W.
It's possible to
W.
ENGLISH 2/16

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Z170reg

Tabla de contenido