Installation 34 A - Wall oven
Technical data
Voltage: 400 V AC 3N 50 Hz
Power consumption: 8,0; 9,0 kW according
to model
Hight: 730 mm at 180 mm fl oor clearance
Width: 375 mm,
Depth: 360 mm
Filling capacity for stones: 15 kg
Stray current: max. 0,75 mA per kW heating
capacity
Sauna oven for use in family sauna
When used for commercial purposes, the
sauna heater may only be used in combi-
nation with the rocker switch Type I Art. No.
94.4421.
The scope of delivery should include
1 sauna oven
1 accessory pack with
1 ea cable reel PG 16
3 ea self-tapping screws B 4.2 X 9.5
4 ea particle board screws
1 set of sauna stones, separately in cloth
bag
The sauna heating unit is intended only for
a supply voltage of 400 V AC 3N.
18
Minimum clearances
The minimum height of the sauna cabin must
be 1.90m on the inside.
The vertical clearance between the upper
edge of the sauna heating unit and the
sauna ceiling is at least 90 cm.
8 cm
1. Center wall mounting over the air intake
vent as in Illust. 2+ 3 and bolt onto cabin
wall with the particle board screws provi-
ded
Wall mounting
GB
Cabin wall
Oven safe-
ty grid
37,5 cm
8 cm
Illust. 1
Air
intake
vent
Illust. 2
Wall mounting
Air intake vent
Illust. 3