DISPLAY: LP30 CONTROL PANEL

STBY
85°C
P1
P1
Boiler ignition or switch-o key
Encoder (wheel), turn to select the various icons on
P2
display, press to access selection
P3
Multiple-function key (advancement through menus etc)
SABATO
27 / 09 /2013
18 : 56
WORK
4
+
-
P3
P2
SUMMER WINTER: the mode allows setting SUMMER or WINTER
operation. In SUMMER mode, the heating system room thermostats are
always satis ed. As well as the areas, the request on behalf of any pu er is
inhibited: the boiler will only work to satisfy the request for domestic hot
water.
In WINTER mode, all requests are considered (DHW, thermostats and
pu er)
ENABLE/DISABLE CHRONO BOILER: if displayed, it allows enabling or
disabling the boiler chrono (see explanation in the relative subchapter
HEATING: the icon indicates the output relative to heating. A steady
icon means that the boiler is satisfying the request; icon o means that
the request is either satis ed or not present; ashing icon indicates that
the boiler is still not prepared to satisfy the request.
DHW STORAGE TANK: the icon indicates the output relative to the
domestic hot water storage tank. A steady icon means that the boiler is
satisfying the request; icon o means that the request is either satis ed
or not present; ashing icon indicates that the boiler is still not prepared
to satisfy the request.
PUFFER: the icon indicates the output relative to the pu er. A steady
icon means that the boiler is satisfying the request; icon o means that
the request is either satis ed or not present; ashing icon indicates that
the boiler is still not prepared to satisfy the request.
+
-