Adjustnthe fi xing latches as shown on
fi gure.
using 4 sheet metal screws.
4. Fit in the sauna heater to the screws
with the suspension slits on the rear side
(fi g.3)
5. Secure the sauna heater by tightening
the 4 screws.
Drill a hole measuring approx. 10 cm in dia-
meter in the cabin wall at the point where the
main power cable is to be inserted. Run the
cable through the hole toward the outside of
the sauna cabin and connect it to the main
power line in a distributor box suitable for
use in moist environments.
This operation must be performed in accor-
dance with the circuit diagram on the control
panel and the regulations of the local EVU
and the VDE.
Caution! The local site installati-
on
fuse capacity and an emergency power cut-
off switch.
Heater
safety
grate
Power cable
25 cm
GB
must provide for suffi cient
Distributorbox
suitable
use in moist
environments
F r e s h - a i r
inlet
Fig. 4
for
21