Must always be placed above the
user (Picture 1.7)
Limit of pendular movement
inferior to 30° (Picture 1.8)
Can not stop a sinking (pul-
verulents or muddy products)
(Picture 1.9)
Precautions of use :
Check that the height of the
anchorage point above the work
space is compatible with the
capacity of the fall arrester and
that sufficient clearance exists,
which is compatible with the
characteristics of the device in the
case of a fall.
Check that during use, the cable
or the webbing does not get
wound around an arm or a leg.
Never try to modify or to repair
PPE; Only the manufacturer or a
certified maintenance centre is
authorised to repair it.
Never connect more than one
person to the fall arrester.
Never block the winding out of
the cable, strap.
The cable or the strap must
always be tensed. In case of "slack",
the equipment must be checked
by the manufacturer.
Lateral movements mustn't
exceed one third of the distance
ground / working surface.
Make your movements on a
normal walking speed. Accelera-
tions, climbs and others engage
the clamping system of the
equipment.
This equipment is designed for a ver-
tical use. If your cable drum has been
designed for a special use (horizon-
tal or inclined) you must follow the
recommendations of the additional
specific instruction.
AIR CLEARANCE
Before using a cable drum, check for
a minimum space clearance below
the user's feet as necessary, to prevent
any collision with the structure or the
ground.
With a weight of 100 kg in a normal
use (cable drum above the head), the
air clearance D is the stopping dis-
tance H + an additional distance A +
1M. A is function of the length of cable
out L and the angle α formed by the
cable (or D, H, A and L in m and α in °)
(Picture 3) (except in special cases -
see specific manual).
ANCHORAGE POINT :
If possible, to be used with achorage
devices (conformed to the EN 795
standard) or structural anchor. that is
8
to say elements fixed to last, to a struc-
ture (wall, post...).
Check that the anchorage point :
has a resistance superior to 12 KN
(Picture 1.10)
is situated above the operator
(Picture 1.7)
vertical to the work surface :
(angle maxi ±30°).
Suits at best the anchoring
system
Does not present sharp edge.
CARABINER
Connector is compliant with standard
EN 362
When the carabiner is used for
attachment to an anchorage point,
check for compliance with the
recommendations of the "ANCHO-
RAGE POINT" paragraph ;
AT THE MOMENT OF CONNECTION
TO THE CARABINER, CHECK
THAT THE LOCKING SYSTEM IS
CORRECTLY IN PLACE
ATTENTION
The carabiner is an essential element
for your safety. We therefore recom-
mend that you:
attribute the connector to
one person in particular, where
possible;
check the carabiner before each
use in order to safeguard against
any distortion, any sign of use and
to verify the good functioning of
the locking system. (Picture 4)
do not attach and remove it seve-
ral times during the same working
day, if it has a manual lock
IN THE SAME WAY, IF THE
CARABINER HAS BEEN USED TO
STOP A FALL, IT IS ESSENTIAL FOR
SAFETY REASONS TO RETURN IT
FOR CHECKS.
PERIODIC EXAMINATION
These instructions must be kept with
the product. Fill in the identification
sheet and enter the markings informa-
tion. This periodic examination, which
verifies the effectiveness and strength
of the equipment is indispensable in
guaranteeing the user's safety (refer
to the paragraph "checks before use").
A qualified person (manufacturer or a
person or organization authorized by
the manufacturer) must examine this
equipment at least once each year (ex-
cept in some specific cases – see the
specific manual), in strict compliance
with the instructions of the manufac-
turer and the examination must be
recorded on the attached sheet. The
frequency of the examination must
be increased in accordance with re-
Tabla de contenido