ALLMATIC
No constant clamping force:
If the clamping force changes, the update interval is 0.5 seconds. The current clamping force is
transmitted to the MEE every 0.5 seconds. As long as the clamping force changes, the update
interval remains at 1 s.
Radio
flashes every 0.5 seconds (2 Hz).
The values of the current clamping force are only recorded as long as the MEE is in
force display mode. If a different mode is selected, values are no longer recorded.
8.4
Coupling Mode
00000
Make sure that solely
1 spindle is spanned!
Coupling=Press SET
Decoupl.=Hold
Fig. 7: Coupling mode
1 Spindle HD
In coupling mode, up to four CA spindlen can be installed. The ID of the CA spindle is displayed
at the coupled position.
8.4.1
Coupling With One CA Spindle
w MEE in coupling mode.
1. Lightly clamp the CA spindle to be coupled.
2. Press the button
to be coupled.
ð The lower display changes to query mode.
Clamp assist
CA011
00000
on the storage space with which the corresponding CA spindle is
00000
SET 5s
Operation | 8
EN
1
43 / 294