Adjusting eye sensitivity:
A
To adjust the sensor first remove the clear plastic
cover from the end of the sensor. There are two
adjustable screws under the cover. One screw is
labeled "GAIN" and is used to set the sensitivity
of the sensor. The other screw is labeled "DO &
LO" and should always be be full clockwise.
B
With the end of the optic cable pointing at the
center of the reflective tap, turn the "GAIN"
screw counter-clockwise until the red L.E.D.
indicator is not on. Then turn the "GAIN"screw
clockwise until the L.E.D. indicator comes on.
Then turn the "GAIN "screw one full turn
clockwise. The L.E.D. indicator should be
blinking slowly. Placing a piece of fabric
between the optic cable and the reflective tape
should cause the L.E.D. to turn off.
14
(770)963-7369 FAX (770)963-7641
Fig. 12
ATLANTA ATTACHMENT COMPANY
401 Industrial Park Dr.-Lawrenceville, GA. 30045
11
Para ajustar la sensibilidad del ojo:
A
Para ajustar el sensor primero quite la cubierta
plástica transparente en el extremo del sensor.
Hay dos tornillos debajo de la cubierta. Un
tornillo está rotulado "GAIN" y es usado para
regular la sensibilidad del sensor. El otro tornillo
dice "DO & LO" y tiene que estar siempre
totalmente en el sentido de las manecillas del
reloj.
B
Con el extremo del cable optica apuntando al
centro de la cinta reflectora, dé vuelta al tornillo
"GAIN" en sentido contrario a las anecillas del
reloj hasta que la luz roja [L.E.D] del indicador
se apaga. Después dé vuelta al tornillo "GAIN"
en el sentido de las agujas del reloj hasta que la
luz [L.E.D] se enciende. Ahora dé vuelta al
tornillo una vuelta completa en el sentido de las
agujas del reloj. El indicador [L.E.D] debe
encenderse intermitentemente muy despacio
Colocar un pedazo de material entre el cable
optica y la cinta reflectora debe hacer que el
indicador [L.E.D] se apague.