We need to confirm the access to this programme by pressing
button no.3 "SET" and it should show up the following screen (see
drawing D48):
We modify the value "OFF" and select "ON": Finally, we introduce
the times to start and stop to complete the desired setting up.
As in the daily programme, if we need to set up only one time to start
and stop, the options START 2 and STOP 2 should indicate "OFF."
It is also possible to schedule one automatic start hour and manual stop hour (or vice versa).
Example:
START 1: 1:08 hours y STOP 00: "off"
or
START 1: "off" and STOP 1: 22:00 hours.
9.4.5

MENU 4. SELECT LANGUAGE

It allows selecting the languages among those available. To access
this menu you have to confirm with button nº 3 "SET" and then,
choose the selected language among available: Spanish, English,
French, Italian, German and Portuguese with buttons nº 1 and 2
(see drawing D49).
9.4.6

MENU 5. STAND-BY MODE

The stove with the "stand-by mode" activated (see drawing D50)
will turn off when the temperature reaches the temperature set plus
a differential (2º C). When the ambient temperature falls to the set
temperature minus a differential (2ºC) the stove automatically restarts
an ignition cycle. It means that if you choose a set temperature of
22ºC the stove wills turn-off when the room temperature is 24º C
and it will restart automatically when the ambient temperature falls
to 20ºC.
In case of the "Stand-by Mode" is deactivated (by default) the stove will work in "modulation work" when it reaches the set temperature and
that allows the temperature set could be higher.
9.4.7

MENU 6. SOUND MODE

By activating this modality, the stove will emit a sound when the
system detects a fault and goes into the alarm state. To access
to this menu you have to confirm with button nº 3 "SET" and then,
choose "on" with buttons nº 1 and 2 (see drawing D51).
9.4.8

MENU 7. INITIAL LOAD

In case of the stove have no more fuel during the operation; to avoid
an anomaly in the next ignition, it is possible to do a fuel pre-load for
maximum time of 90 seconds to load the screw-type conveyor when
the stove is switched off and cold. To start the load press button nº 2
and to stop it press button nº 4. (see drawing D52).
It is very important that the burner is totally clean when you start the stove. So, when the initial load is finished, you must check the
burner is clean of fuel to do correctly the ignition of the stove.
9.4.9

MENU 8. STOVE STATE

It shows up the current state of the stove and provides
information about the devices connected. Therefore,
the user can get a technical information. The next
screens are seen automatically (see drawing D53,
D54, D55 and D56).
SMOKE EXTRACTION SPEED
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
SMOKE TEMPERATURE
FAN 2 AND 3 SPEED (NOT AVAILABLE)
STATE
4
STATE
TIME 1
STATE
STATE
ALARM DELAY
D54
OPERATIONAL STATE
35
Off
M - 3 - 4 - 01
PROGRAMME
WEEKEND
Menu 04
SPA
On
Menu 05
MODE
STAND-BY
On
Menu 06
MODE
SOUND
77"
22º C
LOAD
INITIAL
REMAINING TIME INTERMEDIATE CLEANING
OPERATIONAL STATE
D48
D49
D50
D51
D52
D53
AIR SERIES
Tabla de contenido
loading

Tabla de contenido