Pull down evenly on the entire length of the wiper
blade so that it firmly touches the floor.
Tighten all screws and test run machine for splashing
under the blades.
Do not adjust blades too low, as it will cause damage
and excessive wear to the blades.
Replace Side Skirt Wiper Blades:
Remove the side skirt assembly from the machine.
Remove the retaining strip and screws.
Remove the old wiper blade and replace with a new
blade.
Replace the retaining strip, and screws, do not
tighten.
Pull down evenly on the entire length of wiper blade
so that it firmly touches the floor.
Tighten all screws and test run the machine for liquid
splashing under the blades.
Do not adjust blades too low, as it will cause damage
and excessive wear to the blades.
Sidekick Chemical Dispenser
Purge the lines with clean water after each use.
The squeeze tube under the see-through cover on top
of the pump requires periodic replacement
approximately every 500 hours (depending on
chemicals used).
To replace the squeeze tube:
1. Remove ferrule nuts from pump
2. Unscrew the pump cover, exposing the
squeeze tube.
3. Remove the damaged squeeze tube and
replace with a new squeeze tube.
4. A screwdriver can be inserted in the spinner
hub and rotated as the tube is being replaced to
ease insertion. It is important not to twist the
tube as it is being inserted and the fittings
should be inserted "flat side up"
5. Add grease from the included packet.
6. Re-install cover and resume normal operation.
Daily Maintenance
Battery Charging
The master power switch and all other switches
(except the EMERGENCY STOP) must be turned
OFF.
You must recharge the batteries when indicated by
the battery meter, and after every use. Read the
battery meter while the machine is in use.
*350 AH batteries normally require 14 ½ -16
to fully charge.
NEVER let the batteries sit overnight after the
machine has been run for more than 1 hour since last
recharge.
See Battery Charger section.
Battery Electrolyte (Liquid) Level (Flooded only)
Inspect the electrolyte level of at least one cell in each
battery before charging. The liquid must be visible
above the internal plates. Do not charge the batteries if
the liquid is below the plates.
Add only distilled water to the cell of a battery to
adjust the liquid level. Do not use well or tap water.
Before charging, add only enough water to cover the
top of the internal plates. After charging, add only
enough water to bring the level to the bottom of the fill
tube.
Do not overfill the battery liquid level, this will cause
electrolyte (acid) spill. Spilled electrolyte (acid) can
cause machine damage and personal injury. Clean
up and dispose of all spills immediately.
See the battery-warning sheet (page 3) for more
details.
If machine is equipped with battery Auto-Fill system,
fill batteries prior to charging.
Battery Packages
The Wrangler 2730 or 3330 is a 36-volt system and is
available with two battery packages:
Six (6) 6-volt, 235 Amp Hour Batteries.
Six (6) 6-volt, 350 Amp Hour Batteries.
Consult your local NSS authorized distributor for
application recommendations
Solution and Recovery Tanks
The recovery tank is emptied through a large rubber
hose at the front of the machine. Remove the plug
and drain the liquids according to your local and
federal regulations.
Every time you empty the recovery tank, we
recommend that you add at least 4 to 6 ounces
[120mL to 175mL] of defoamer chemical into the
recovery tank before resuming work. Vacuum the
defoamer into the empty recovery tank through the
squeegee vacuum hose.
At the end of the day empty all liquids from both
solution and recovery tanks. Rinse both tanks with
clean water to prevent chemical residue build-up,
allow to air - dry to prevent odors.
Remove any residue from screen and float ball to
ensure proper operation. Replace float assembly in
recovery tank.
Check clear lid for airtight seal.
Check the drain hose for damage.
Inspect and clean the vacuum filter located under the
top metal plate. Every 50 hours.
Pad Drivers or Brushes
Remove either pad drivers or brushes from machine
after use.
Rinse with clean water to prevent chemical residue
build-up. ***NOTE: prolonged exposure to some wax
1
/
hours
2
stripper brands may degrade the material. Rinsing
after use in a wax floor stripping application is highly
recommended.
Allow to air-dry by installing in drying position on front
of solution tank, on a peg or upside down on a shelf.
Inspect for wear or damage. Repair or replace as
needed.
Squeegee Assembly
Remove squeegee assembly from machine.
Rinse with clean water to prevent chemical residue
build-up. ***NOTE: prolonged exposure to some wax
stripper brands may degrade the squeegee material.