• Flushing of the mineralisation cartridge PURITY C500 MinUp
Step
• Connection of the enclosed flushing head to the membrane cartridge
#3
PURITY C150 PROGUARD
• Flushing of the post-filter cartridge PURITY C50 Fresh
Flushing of the mineralisation cartridge:
• Open the mains water supply valve
• Open the shutoff valve
• Flush the mineralisation cartridge: Open the flush valve of the pre-filter head by pushing
the grey slider outwards. Flush 2 bed volumes (1 bed volume equals 5.4 litres). While
flushing, continue with step 3.3
3.2
Connecting the enclosed flushing head to the membrane cartridge PURITY C150
PROGUARD while the mineralisation cartridge is being flushed in the pre-filter head (step 3.2):
• Make sure the locking handle of the flushing head is open. The locking handle is open
when the two blue handles are in an inclined position.
• Connect the flushing head to the membrane cartridge. Close the locking handle of
the flushing head by bringing its two blue handles in a horizontal position
• Insert the longest of the three tubes of the flushing head into the flushing head valve
3.3
2x
EN