Discharge Direction:
wARNING!
Before installing remove the knock-out plate that close the air outlet on the top if is
desired to use the range hood for vertical discharge OR the rear outlet if is desired to
use the range hood for horizontal discharge. (see also Figure below).
wARNING!
ONCE ThE KNOCK OUT PLATE hAS BEEN REmOVED, ThIS CANNOT BE REINSTALLED ANymORE
TO CLOSE ThE AIR OUTLET
To change to horizontal discharge, do the following (see also Figure below):
a. Remove knock-out plate on the rear side of the hood (see also Figure below)
b. Remove and keep the 4 screws (2 per side) that fix blower on top of the hood and release
it from keyholes.
c. Rotate the blower 90° and check that pins on side blower fixing brackets fit into the preinstalling holes .
d. Fix the blower on the rear side with the same 4 screws (see step b).
. Assembly of the 8" Transition:
The transition supplied with the hood mounts to the top or rear of the hood.
Note- Cabinet installation with vertical discharge ONLY: do not install transition until hood has been fixed on
cabinet.
a.
Place the transition piece over the hood
exhaust and secure with 4 screws provided (Figure below).
b.
Duct tape connection between transition and hood.
Vertical discharge Knockouts
Vertical discharge Knockouts
Keyhole
Pin
V E R T I C A L D I S CHAR GE
HO RI ZO N TAL D I SCHAR GE
Pin
1
Knockouts (junction box)
Top screw location
Square slot
Bottom fixing screw location