Technical Data; Ec Declaration Of Conformity - EUCHNER N01 Serie Manual De Instrucciones

Finales de carrera unitarios de precisión
Ocultar thumbs Ver también para N01 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Operating Instructions
Precision Single Limit Switches N01/NB01/SN01
sealing of cable entry
f
loose cable connections or plug connectors.
f
Information: The year of manufacture can be seen
in the bottom, right corner of the rating plate.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
correct use stated above, or if the safety instruc-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.
Notes about
The following information applies to devices
with cable entry:
For use and applications as per the requirements
of
, a copper wire for the temperature range
60/75 °C is to be used.
The following information applies to devices
with plug connector:
For use and applications as per the requirements of
, a class 2 power supply according to UL1310
must be used. Connection cables for safety switches
installed at the place of use must be separated
from all moving and permanently installed cables
and un-insulated active elements of other parts
of the system which operate at a voltage of over
150 V. A constant clearance of 50.8 mm must be
maintained. This does not apply if the moving cables
are equipped with suitable insulation materials which
possess an identical or higher dielectric strength
compared to the other relevant parts of the system.

EC declaration of conformity

The manufacturer named below herewith declares
that the product fulfills the provisions of the direc-
tive(s) listed below and that the related standards
have been applied.
EUCHNER GmbH + Co. KG
Kohlhammerstr. 16
D-70771 Leinfelden-Echterdingen
Directives applied:
Machinery directive 2006/42/EC
f
Standards applied:
EN 60947-5-1:2004 + Cor.:2005 + A1:2009
f
EN 1088:1995+A2:2008
f
EN 14119:2013
f
The original EC declaration of conformity can also
be found at: www.euchner.de
Service
If service support is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
D-70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
Fax:
+49 711 753316
E-mail:
Internet:
www.euchner.de

Technical data

Parameter
Value
Housing material
Die-cast aluminum,
anodized
Plunger material
Stainless steel
Degree of protection
IP 67
acc. to IEC 60529
Mech. operating cycles
30 x 10
Ambient temperature with switching element
ES550/553/556/558/562/620
-5 ... +80 °C
ES572 (high temp. version)
-5 ... +125 °C
(200 h at 180 °C)
-25 ... +70 °C
ES588
ES560/593
-5 ... +125 °C (manufac-
turer's data max. +140 °C)
Installation position
Any
Max. approach speed
Plunger
Chisel D
20 m/min
Roller R (slide bearing)
50 m/min
Ball K
8 m/min
Min. approach speed
0.01 m/min
Actuating force with switching element ≥ 15 N
Switching element
ES550/553/556/560/562/572/
1 changeover contact
593/620
ES558
1 NC contact + 1 NO
contact
1 positively driven contact
ES588
Switching principle
ES550/553/556/558/560/562/
Snap-action switching
572/593/620
contact
Positively driven slow-ac-
ES588
tion switching contact
Switching hysteresis
ES550/553/556/560/562/572/
max. 0.1 mm
593/620
ES558
0.5 mm
Connection
ES550/558/560/562/572/593
Soldered connection
ES553/556/588/620
Screw terminal
Tightening torque of screw terminal
ES553/556 (hexagon socket head
screw, AF 1.27 mm)
0.2 Nm
ES588 (slot head screw)
0.3 Nm
ES620 (slot head screw)
0.5 Nm
Conductor cross-section
ES553/556/620
0.14 ... 1.0 mm²
ES588
max. 1.5 mm²
Contact material
ES550/553/556/558/572/588/
593/620
Silver
ES560/562
Gold cross cut contacts
Rated impulse withstand voltage
with cable entry
U
imp
with plug connector, 4-pin
U
imp
with plug connector, 5-pin
U
imp
Rated insulation voltage
with cable entry
U
= 250 V
i
with plug connector
U
= 50 V
i
with B-coded plug connector
U
= 250 V
i
Rated short-circuit current
100 A
Rated data for the switching elements
ES558
Conventional thermal current I
10 A
th
Utilization category AC-15
230 V/4 A
Utilization category DC-13
24 V/3 A
Min. switching current at
10 mA
Switching voltage
DC 5 V
Short circuit protection
10 A gG
Mechanical life
Up to 10 x 10
cycles
ES550/553/556/620
Conventional thermal current I
6 A
th
Utilization category AC-15
230 V/2 A
Utilization category DC-13
24 V/2 A
Min. switching current at
10 mA
Switching voltage
DC 24 V
Short circuit protection
6 A gG
Mechanical life
Up to 10 x 10
cycles
5
ES560
Conventional thermal current I
Utilization category DC-12
Min. switching current at
Switching voltage
Short circuit protection
Mechanical life
6
Ideal application
ES562
Conventional thermal current I
Utilization category AC-12
Utilization category DC-13
Min. switching current at
Switching voltage
Short circuit protection
Mechanical life
ES572 (high temperature version)
Conventional thermal current I
Utilization category AC-15
Utilization category DC-13
Min. switching current at
Switching voltage
Short circuit protection
Mechanical life
ES588
Conventional thermal current I
Utilization category AC-15
Utilization category DC-13
Min. switching current at
Switching voltage
Short circuit protection
Mechanical life
ES593
Conventional thermal current I
Utilization category AC-15
Utilization category DC-13
Min. switching current at
Switching voltage
Short circuit protection
Mechanical life
Rated data with plug connector
N01.550SVM5
Utilization category AC-15
Utilization category DC-13
N01.550C1526
Utilization category DC-13
SN01.558SVM5
= 2.5 kV
Utilization category AC-15
= 2.0 kV
Utilization category DC-13
= 1.5 kV
Reliability values acc. to EN ISO 13849-1 for NB01 with
switching element ES588
B
10d
Preferred approach directions
120
-0,5
D = chisel
Figure 2: Plungers and approach directions
operating
6
operating
6
2 A
th
30 V/1 A
1 mA
DC 5 V
2 A gG
Up to 10 x 10
operating
6
cycles
1 mA/5 V ... 0.3 A/30 V
0.1 A
th
30 V/0.1 A
30 V/0.1 A
5 mA
DC 5 V
0.125 A gG
Up to 15 x 10
operating
6
cycles
5 A
th
230 V/4 A
24 V/1 A
10 mA
DC 12 V
5 A gG
5 x 10
5
operating cycles
(or 100 h at 204 °C;
manufacturer's data)
10 A
th
230 V/4 A
24 V/3 A
1 mA
DC 5 V
10 A gG
Up to 10 x 10
operating
6
cycles
3 A
th
230 V/3 A
24 V/1 A
10 mA
DC 24 V
3 A gG
5 x 10
operating cycles
5
(manufacturer's data 5 x 10
)
6
30 V/2 A
24 V/2 A
24 V/2 A
30 V/4 A
24 V/3 A
2 x 10
7