GiBiDi SR2 Instrucciones Para La Instalación página 9

Ocultar thumbs Ver también para SR2:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SR2
• The installer shall provide for the installation of a device (for ex. magnetothermic switch) garanting the omnipolar
sectioning of the power supply mains.
• Standards require a minimum contact separation of 3 mm at each pole (EN60335-1).
• Use fittings complying with protection rating IP44 or higher to connect flexible and not flexible pipes or fairleads.
• Installation requires deep knowledge of electricity and mechanics and shall only be carried out by skilled
professionals who shall issue a type. A Declaration of Conformity for the complete installation (EC 89/392
Machinery Directive, Appendix IIA).
• Following standards for motorised doors shall apply:
- EN 12453, EN 12445, EN 12978
And local regulations.
• The electrical system for the automation shall be done to perfection and shall meet current standards.
• The pushing force adjustment of the door shall be measured with a special instrument and adjusted in accordance
with the maximum allowed values of EN 12453 standard.
• The use of an emergency button to be installed near the automation is recommended (connected to the STOP input
on control board).This will stop the gate immediately in case of danger.
• Connect the motor earth wire to the earthing system of the power supply.
NOTES FOR THE INSTALLER
1. If more than one control box is installed, the distance between control boards shall be at least 3
meters to allow the correct working of the radio receiver.
2. The control station has no sectioning device for 230 Vac power supply mains. A special sectioning
device shall be provided for during installation.
3. Use fairleads for control station wires.
4. When not in use, the usually closed inputs (NC) shall be connected with cordless plug.
CONNECTIONS ON THE TERMINAL BOARD
1
2
3
4
1. INPUT 230 VAC LINE (PHASE)
2. INPUT 230 VAC LINE (NEUTRAL)
3. OUTLET LIFTING MOTOR
4. OUTLET COMMON MOTOR
5. OUTLET LOWERING MOTOR
6. OUTLET 230VAC BLINKING LIGHT
7. OUTLET 230VAC BLINKING LIGHT
5
6
7
8
9
10
11
8. OUTLET SERVICE POWER FEED AT 24 VAC 3W
9. OUTLET SERVICE POWER FEED AT 24 VAC 3W
10. INPUT OPEN-CLOSE CONTROL BUTTON (NA)
11. INPUT COMMON
12. INPUT SECURITY DEVICE (NC)
13. INPUT HOT POLE ANTENNA
14. INPUT GROUND ANTENNA
UK
12
13
14
9
Tabla de contenido
loading

Este manual también es adecuado para:

As07000

Tabla de contenido