RISCO Group WatchIN RK325DT Instrucciones De Instalación página 20

Detector industrial de doble tecnología
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Zones Miscellaneous: BUS Zone
Quick Keys
Parameter
[2][0][3][zzz]
LEDS
[1]
Defines the LEDS operation mode
[2][0][3][zzz]
Off
[1][1]
Disables the LEDS operation
[2][0][3][zzz]
Red Only
[1][2]
Only the Red led will operate. This option is highly recommended to avoid
the possibility that the intruder will "Learn" the detector behavior.
[2][0][3][zzz]
3 LEDS
[1][3]
All 3 LEDs will operate.
[2][0][3][zzz]
Detection Sensitivity
[2]
Defines the sensitivity of the detector(MW + PIR)
[2][0][3][zzz]
Sensitivity Options
[2][1]..[4]
1) Low
2) Medium
MW Range
[2][0][3][zzz]
[3]
Defines the microwave channel range (maximum range - 27m)
[2][0][3][zzz]
MW Range options
[3][1]..[7]
1) Minimum
2) 20%
[2][0][3][zzz]
Alarm Logic
[4]
Determine the detector's logic of defining an alarm.
[2][0][3][zzz]
PIR and Microwave
[4][1]
Alarm is activated when both PIR and MW channels detect an alarm
(AND Logic)
PIR or Microwave
[2][0][3][zzz]
[4][2]
An alarm is activated when either PIR or MW channels detect an alarm (OR
Logic)
[2][0][3][zzz]
Lens Type
[5]
Defines the actual Lens of the detector
[2][0][3][zzz]
Lens Type Options
[5][1]..[2]
1) Wide Angle 2) Barrier
[2][0][3][zzz]
Anti-Mask
[6]
Defines the operation of Anti Masking detection
Anti-Mask Options
[2][0][3][zzz]
[6][1]..[2]
1) Disable 2) Enable (Default)
Quick Keys
Parameter
[2][0][3][zzz]
Arm/Disarm
[7]
Defines the operation of the LEDs and the anti masking detections while the
detector is armed
[2][0][3][zzz]
No
[7][1]
AM (Anti masking) is enabled
LEDs behave according to the LEDs parameter definition
[2][0][3][zzz]
Yes
[7][2]
AM (anti masking) is disabled
LEDs are disabled
[2][0][3][zzz]
Green line
[8]
The WatchIN includes a Green Line feature that follows environmental
18
3) Normal
4) ACT (Anti-Cloak™ Technology)
3) 40%
5) 80%
4) 60%
6) Maximum
WatchIN Installation Manual
Default
3 LEDS
Normal
Trimmer
7) Trimmer (MW is
defined by the trimmer
setting on the PCB)
PIR and Microwave
Wide Angle
Enable
Default
No
Yes
Tabla de contenido
loading