ZEP716
1
2
3
1(-) 2(+) 3
ForceBus
1
3 4
4
PS/2
AC OK
5
LOW BATT
+13.8V
GND
DC
6
ZEP716 Self-Powered 16-Zone Expansion Module
The ZEP716 expansion module allows the installation of additional 16 zones to the FORCE Series intruder alarm systems. The module
includes the ZEX516 expansion module and a 13.8V to 4.2A power supply. It is assembled in a metal case, that is designed to carry a
lead-acid backup battery (not supplied), and has a hinged cover.
The ZEP716 includes the PS-2 that serves as a battery charger, that can indicate on AC loss and low battery states.
Warning
Do not use the ZEP716 near water.
Do not operate or touch the module with wet hands.
Do not open the case when it is connected to AC power.
Use a grounded 3-wire power cord. Connection to AC power must be done by a qualified electrician.
This module is intended for indoor use only.
Do not operate or place this module in a humid or dusty location.
Do not operate this unit in direct sunlight or near any heat source.
Technical Specifications
See the ZEX516 specifications above.
Input Voltage: 220-240VAC +10%, -15%
Output Voltage: 13.8VDC, +- 0.5V
Output Current: 4.2A
Case sizes: 26 X 33 X 9 cm
Content of the product package
ZEP716 mounted in a metal case with a hinged door
How to mount and install the ZEP716
Mount the ZEP716 on a flat surface. Follow the next steps.
1.
Open the door, lift and remove it.
2.
Use the holes on the back side of the box or break the side knock outs and pass the zones and
bus wires.
3.
Mount the case on a flat surface, using the keyholes.
4.
Set the ZEX516's ID no. DIP switch; see the settings above.
5.
Connect the wiring.
6.
Connect to mains.
7.
Close the box's door.
8.
Test the module using the
1
2
3
4
5
6
7
8
9
9
4
NC Com NO
TAMPE R
RELAY 1
1
8
-
2
7
3
4
5
6
7
8
9
Test and Diagnostics
menu.
Tamper Switch
Power Supply
230VAC Input
Grounding Bolt
PS-2 Power Supply
13.8V to 4.2A Power Output
12V/5-7Ah, Backup Battery
(Not Supplied)
Bus Wires; Wire #2 (+) Not
Connected
ZEX516 Module
Interruptor contra sabotaje
(Tamper)
Fuente de alimentación
Entrada 230VAC
Tornillo para Tierra Física
Fuente de alimentación PS-2
Salida de corriente 13.8V a 4.2A
Batería de respaldo 12V/5-7Ah,
(No incluida)
Cables del Bus; El cable #2 (+)
No está conectado.
Módulo ZEX516
weight: 3.6kg
Battery Indication: Open Collector. Low=Battery OK, High=Low Battery
AC Indication: Open Collector. Low=AC OK, High=AC Loss
CE Compliance
Operating Temperature: -10 to +55°C
Humidity: 93% R.H., Non-condensing
This guide
-6-
1
Внешний Тампер вскрытия короба
2
Источник питания
3
Клеммы подключения питания
230В AC
4
Заземление
5
Источник питания PS-2
6
Выход 13.8В 4.2А
7
АКБ 12В/5-7Ач (не входит в
комплект поставки)
8
Шина BUS; провод №2 (+) не
подключается
9
Расширитель ZEX516
)הגנה (טמפר
230VAC
מתח הזנה
בורג הארקה
PS-2
13.8V
- ל
4.2A
יציאת מתח
(לא
12V/5-7Ah
סוללת גיבוי
2
'. חוט מס
Bus
-
כבל חיבור ל
(+) לא מחובר
ZEX516
26/26.5 cm
מפסק
1
ספק כח
2
3
4
ספק כח
5
6
7
)מסופק
8
מרחיב
9