Technical Specifications; Ordering Information - Pima ZEX516 Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ZEX516 Remote 16-Zone Expansion Module
The ZEX516 expansion module allows the installation of additional 16 zones to the FORCE Series intruder alarm systems. The module
connects to control panel's bus. It has a tamper switch for detecting the opening of its box, and a buzzer for help the technician in
locating it on the premises. It is supplied mounted in a standard plastic box. The expansion module does not support zone doubling.
For complete zone programming information, refer to the FORCE's Installation guide (P/N: 4410459).

Technical specifications

 Number of Zones: 16 (can be EOL supervised)
 Operating Voltage Range: 10-15VDC
 Current Consumption: 30mA
 Box Dimensions: 19 X 13 X 4cm (Module: 8.2 X 15 X 1.6cm)
Content of the product package
 ZEX516 module mounted in a plastic box
How to mount and install the ZEX516
Mount the ZEX516's box on a flat surface. Follow the next steps.
1.
Open the screw at the bottom of the box and remove the cover.
2.
Remove one or more knock outs and pass the wiring through it.
3.
Mount the box using the mounting holes.
4.
Set the module's ID-no. DIP switch (no. 13 in the figure above + the settings figure).
5.
Connect the wires of the zones and the bus.
6.
If the external tamper input (no. 2 in the figure above) is not in use, connect it to minus.
7.
Set the module in the control panel (refer to the FORCE's Installation guide) and check the LEDs.
8.
Close the cover and fasten the screw.
9.
Test the module using the
The LEDs
The ZEX516 has two LEDs, described below.
LED label
Color and state
Red blinks
RUN
Red off
Green blinks
BUS
Green solid
Green off
Tampers disconnection jumper
The jumper on the circuit board is used for disconnecting the onboard tamper and the external tamper input, as described below:
 Jumper open: tampers connected (use only one tamper)
 Jumper closed: tampers disconnected

Ordering information

 ZEX516: P/N 8500027
1
Revision 00.39.2D and higher
 This guide
Test and Diagnostics
menu.
Description
Module runs OK
Voltage fault
Data transfer
Module is not set in the control panel
Bus connection fault
 Weight: 355gr (gross)
 CE Compliance
 Operating Temperature: -10 to +55 °C
 Humidity (Max.): 93% R.H., Non-condensing.