Maintenance - Depuragua RO-50G-A01 Manual De Instalación Y Mantenimiento

Unidad doméstica de osmosis inversa
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MANUAL/NOTICE DÌNSTALLATION/MANUALE DI INSTALLAZIONE (MODELS RO A01 &E01)

8. MAINTENANCE

To ensure that the system works at its optimum level, they must perform certain maintenance
routines. Maintenance frequency will depend on the level of use, as well as the quality of the inlet
water
8.1 Membrane Cleaning:
Every 3 or 4 weeks open drain (Part 13) key for 3 minutes to perform a backwash membrane
washing, then you leave the key in closed position
8.2 Filter replacement:
Replace PP10 pre-filter every 3 to 6 months depending on the quality of the raw water and
consumption.
Switch GAC10 prefilter and CTO10 every 6 to 12 months.
Membrane change every 24 to 36 months, in areas of hard water (with high lime) replacement will
be held every 12 months
Post Carbon T33 filter change every 6 to 12 months.
If you do not use the system for a long time (it is vacation, travel, etc.) Please be sure to
disconnect the power supply, cutting the water supply and drain the tank.
8.4 How to change cartridges and membrane.
Prior to the change:
1.0 Unplug the equipment from the electrical outlet (A01)
1.1 Valve water supply (1)
1.2 Close the valve of the tank (14). Open faucet to release pressure
1.3 Carry out disinfection of the equipment at the same time that performs the following steps (see
point 8.5)
Change of pre and post filters
1.4 Unscrew container vessels of the filter (with racket key)
1.5 Changing the filters and thread the vessels with the racket spanner
1.6 Change T33 post-filter.
Change of membrane
1.7 Disconnect the tubing from the porta head membrane
1.8 Unscrew carrier head membrane with the key.
7
Tabla de contenido
loading

Este manual también es adecuado para:

Ro-75g-a01Ro-100g-a01Ro-50g-e01Ro-75g-e01Ro-100g-e01