THERMEx Top Link Modul I Instrucciones página 72

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

72
THERMEX TOP LINK MODUL
As default, the light is turned on when the hood goes into after-running when the hob is turned off. If you want the light to turn off when the hood
goes into after-running, it can be set via dipswitch 4.
NOTE: This ONLY applies when connecting to the hob.
The light is turned on in the after-running
SETTING OF SET POINT FOR HOB
Top Link is set as standard to start the hood at a minimum load of 200 Watt when it is controlled from the hob. Top Link does not need to be
adjusted, but is ready for use after installation via the hob's power supply.
To start at a different minimum load, it is set in the following way:
1.
Turn on the hob at the minimum load selected.
2.
Hold down the "Set level" button until the yellow LED "Set 1" starts to flash rapidly.
3.
When the "Set 1" LED is lighting constantly, the set point is set.
4.
Turn off the hob. NOTE: The yellow "Set 1" LED must turn off when the hob is turned off, otherwise the set point must be set again.
Top Link is now ready for use with the hob.
NOTE: You can reset to factory settings by holding down the set point button for about 3 seconds.
SETTING OF SET POINT FOR OVEN
Top Link is set as standard to start the hood at a minimum load of 200 Watt when it is controlled from the oven. Top Link does not need to be
adjusted, but is ready for use after installation via the oven's power supply.
To start at a different minimum load, it is set in the following way:
1.
Set the oven to the selected minimum load.
2.
Hold down the "Set level" button until the yellow LED "Set 1" starts to flash rapidly.
3.
When the "Set 1" LED is lighting constantly, the set point is set.
4.
Turn off the oven. NOTE: The yellow "Set 1" LED must turn off when the oven is turned off, otherwise the set point must be reset again.
Top Link is now ready for use together with the oven.
NOTE: You can reset to factory settings by holding down the set point button for about 3 seconds.
The light is turned off when the hood goes into after-running
M 536991200913062017