5. PROGRAMMING THE OPERATOR
5.1
5.1.1
Keep trolley locked, pull and push the door by hand, make sure the trolley connects with the shuttle.
Turn on the power, the courtesy light is on for several seconds, at the same time, the LED displays the number
5.1.2
from "99" to "11". Then the operator turns to standby situation.
5.1.3
At last, it displays "- -"
5.2
5.2.1
Press and hold SET until it displays "P1".
5.2.2
Press SET, it displays "OP"
5.2.3
The press and hold UP, it flashes "OP".
5.2.4
When the door has reached the open position, press SET, it displays "CL"
5.2.5
Then press and hold DOWN, it flashes "CL". When the door has reached the closed position, press SET.
5.2.6
The door opens and closes automatically to map the open and close sensitivity force requirements.
5.2.7
It displays "- -" to show setting is complete.
5.3
5.3.1
Press CODE, it displays "Su".
5.3.2
Press a button on the transmitter, then release and press the same button again, "Su" flashes.
Then it displays "- -" to show setting is complete. Repeat up steps to code a maximum of 20 different transmitters
5.3.3
and/or buttons
5.4
When the unit has stores 20 codes, it flashes "Fu", or preventing coding mistakes, it is necessary to cancel all the
5.4.1
stored codes.
5.4.2
Press and hold CODE, it displays "Su".
5.4.3
Hold more than 8 seconds, it flashes "dL", all the codes were cancelled.
5.5
5.5.1
Press and hold SET, it displays "P1".
5.5.2
Press UP once, it displays "P2".
Press SET once again, it will show the corrent situation.
5.5.3
Press UP to increase the force one degree or press DOWN to decrease one degree. Maximum degree is "F9",
minimum is "F1".
5.5.4
Press SET to confirm. The default setting is "F5".
After finishing all the setting, please check the force to make safe.
PREPARING
SETTING OPEN AND CLOSE POSITIONS
ADDING OR CHANGING TRANSMITTERS
SELF LEARNING TRANSMITTER
FORCE ADJUSTMENTS
39
EN