ORNAMENT LIGHT INSTALLATION
Check that the installation is done correctly before
switching on the appliance. The connection has to be
made in accordance with local regulations. Carefully check
that the leads are properly connected. If in doubt, consult a
qualifi ed electrician.
• Main secondary (low voltage cable) must not be buried
to a depth of greater than 6 inches (15.2 cm).
• The cord should be protected from abrasion, cuts and
any other damage.
• Do not use the ornament light for any other purpose
other than that for which it is intended.
• Do not use this appliance in swimming pools or other
applications where people are immersed.
• This ornament light is made to function completely
immersed in water at temperatures between 5°C and
25°C (40ºF and 77ºF). Do not use in conditions where
temperature drops below freezing (0°C / 32°F)
• All installer completed cable connections must be
located outside of the pond or fountain.
LOCATION OF THE TRANSFORMER
When planning where to install the transformer, make sure
that the power cord is long enough to extend from the
electrical socket into which you will plug the transformer
to the point where you will mount the transformer.
Transformer must be in sheltered location a minimum of
1 m (39") above ground.
MOUNTING THE TRANSFORMER
DO NOT USE EXTENSION CORDS!
DRIP LOOP
Mount the transformer horizontally on a solid surface
beyond the reach of small children and at least 1 m (39")
APPLIANCE
POWER
SUPPLY
CORD
above the ground.
Transformer Mounting: Secure the transformer to the
mounting surface with either #8 x 1" round head wood
screws or if mounting on a concrete/brick surface use an
appropriate masonry anchors. Utilizing the two preformed
tabs extending from the transformer housing securely
fasten to the mounting surface.
PLUGGING IN THE TRANSFORMER
After the light and transformer have been properly
installed, plug the transformer power cord into a GFCI
protected socket.
WARNING (for U.S.A. and Canada only): This appliance
has a polarized plug (one blade is wider than the other).
As a safety feature, this plug will fi t in a polarized outlet
only one way. If the plug does not fi t fully in the outlet,
reverse the plug. If it still does not fi t, contact a qualifi ed
electrician. Never use with an extension cord unless plug
can be fully inserted. Do not attempt to defeat this safety
feature.
ADDITIONAL INSTRUCTIONS FOR U.K. ONLY
Transformer without plug
This product is designed to be permanently wired to the
mains supply in a dry weatherproof enclosure through a
double pole switched fused spur which complies to
BS3676, fi tted with a 3 Amp fuse. The installation
must conform to the regulations of the Local Electricity
Authority which could include the use of a plastic or
metal conduit to protect the cable. A 30 mA Residual
Current Device 'RCD' must be fi tted to the mains supply.
IMPORTANT - The wires in this mains lead are coloured
in accordance with the following code:
BROWN - LIVE BLUE - NEUTRAL
The Brown lead should be connected to the Live
terminal, which may be marked with an 'L' or coloured
brown or red.
The Blue lead should be connected to the Neutral
terminal, which may be marked with an 'N' or coloured
blue or black.
The cord should be protected from abrasion, cuts or any
other damage.
The socket must be positioned in a dry and protected
place.