2.6
Only for sectional and spring operated garage doors
Fasten the draw slide I on the upper portion of the door
maintaining the previously marked reference points.
Connect the perforated bar L and the curved arm M using
2, 6 x 15 bolts. Connect the curved arm M and the draw
plate I using the cylindrical headed pivot with the provided
split pin.
2.7
Only for counter-weighted garage doors
Fasten the arch arm J4 on the upper portion of the door
maintaining the previously marked reference points.
The two anchor plates (upper and lower) of the arch J4
must be in the same plane. If not, add shims.
Connect the perforated bar L to the perforated bar of the
arch arm using 2, 6 x 15 bolts.

INTERNAL RELEASE

To release the actuator, it is only necessary to pull the knob
downwards.
CAUTION: Do not use the knob to open the door.
It is prohibited to hand objects off the release cord.

ELECTRICAL CONNECTIONS

The control panel inside MOOV-SEZ50 is already cabled.
You just need to plug it in the electrical outlet to proceed with
operational parameter programming.
If using photocells, they must be connected as follows: