Indoor Unit Wiring
1. Prepare the cable for connection
a. Using wire strippers, strip the rubber jacket
from both ends of the signal cable to reveal
about 15cm (5.9") of the wire.
b. Strip the insulation from the ends of the wires.
c. Using a wire crimper, crimp the u-lugs to
the ends of the wires.
2. Rotate the sensor device's installation bearer to
the other side. Then remove the cover of the
electrical box. (Also, remove the electrical box
also if its capacity is 18000btu/h and has
networking functionality.)
3. Connect the u-lugs to the terminals.
Match the wire colors/labels with the labels on
the terminal block, Firmly screw the u-lug of
each wire to its corresponding terminal. Refer
to the Serial Number and Wiring Diagram
located on the cover of the electric control box.
Installation bearer
of sensor device
Wiring diagram
Power Specifications
MODEL(Btu/h)
PHASE
POWER
FREQUENCY AND VOLT
CIRCUIT BREAKER/FUSE(A)
INDOOR UNIT POWER WIRING(mm²)
OUTDOOR UNIT POWER WIRING
INDOOR/OUDOOR
STRONG ELECTRIC SIGNAL
CONNECTING
WIRING(mm²)
WEAK ELECTRIC SIGNAL
GROUND WIRING
Magnetic ring
accessories)
•
•
4. Clamp down cable with the designated cable
5. Reinstall the electric box cover and the front
Control box
Connective wiring
diagram
<16K
1 Phase
220-240V~, 50Hz/60Hz
20/16
——
3x1.5
4x1.0
(if supplied and packed with the
1 2 3
CAUTION
While connecting the wires, please
strictly follow the wiring diagram.
The refrigerant circuit can become very hot.
Keep the interconnection cable away from
the copper tube.
clamp to secure it in place. The cable should
not be loose, and should not pull on the u-lugs.
panel of the indoor unit.
220-240V~, 50Hz/60Hz
——
1.5
Pass the belt through
the hole of the Magnetic
ring to fix it on the cable
16K~18K
1 Phase
20/16
3x1.0
3x2.5
——
3x0.2
2.5
Page 35
V.2