NOTICE
The core colors only apply if Leuze electronic's original connection ca-
bles are used (see operating instructions, chapter "Cables acces-
sories").
HOST/Ethernet, M12 socket, D-coded
Pin No.
Designation
1
TD+
2
RD+
3
TD-
4
RD-
Thread
FE (functional
(M12
earth)
socket)
IP address
Factory settings for the network address of the code readers of the DCR 200i se-
ries:
– IP address: 192.168.060.101
– Subnet mask: 255.255.255.0
Technical data
NOTICE
Additional technical data and notices on using the device can be found
in the operating instructions for the code reader.
Operating voltage
Average power consump-
tion
Integrated LED illumination Red (616 nm)
Assignment
Transmit Data +
Receive Data +
Transmit Data -
Receive Data -
Connection cable shield.
The shield of the connection cable is on the
thread of the M12 socket.
18 ... 30 V DC
PELV, Class 2 / SELV
8 W / 12 W with heating (without load on the switch-
ing output)
During strobed operation, a higher power can briefly
be consumed.
Risk group 0 (exempt group) in acc. with
EN 62471:2008
Infrared (850 nm)
Risk group 1 in acc. with EN 62471:2008