Inserting a new filter: If you are using a prefilter or
an odourfilter, fix it around the new filter as tight as
possible and stick the ends together using the sticky
tape which is prepared on the prefilter/odourfilter.
Put the filter back into position using the same
rotating motion and gently push until it fits well on
the body of the unit . Cover the filter with the silver
filter cover. Pay special attention to snap the cover
properly (on both sides).
CA CHEMICAL
The blower unit CACH DF may be used only with all
three filters installed.
Stricly use three identical filters at one go (one set
of 3 filters).
CA CHEMICAL
- Selection of the filter acc. to the type of contamination
Ordering code
Filter type *
50 00 48
P R SL
50 01 56
A
50 01 57
AP R SL
50 01 67
ABP R SL
50 01 68
ABEKP R SL
6.2. Batteries
NOTE ! Batteries are delivered
batteries must be charged before they are used for
the first time. The battery can be charged
separately or on the blower unit.
The charger must not be used for any other
purpose than that for which it was manufactured.
Do not charge the battery in a potentially explosive
atmosphere. The battery charger is intended for
indoor use. It must be protected against damp. The
charger controls the charging automatically. After
the battery has been charged, the charger switches
to the trickle charging regime and keeps the battery
fully charged. The charging time is 10 to 14 hours
depending on the type of battery.
6.2.1.

Battery charging

1. Check that the voltage of the electrical power
supply is correct.
2. Plug the charger into the socket.
3. Connect the battery to the charger. The socket
of the battery is positioned on the back side.
The charging regime is signalised by a red LED
diode light.
4. After charging has been completed, the trickle
charging regime is activated:
- charger for CA BASIC: red LED diode goes
Colour code
White
Brown
Brown
White
Brown
Grey
White
Brown
Grey
Yellow
Green
White
* Filtres for CleanAIR blower units are marked acc. to EN 12 941
The grid needn´t list all available types of filters, contact your supplier for complete current offer.
discharged. All
CHANGING THE FILTER OF CA CHEMICAL
see picture supplement no.2
pict. 2A :
Dismount the filters from the unit by unscrewing
them one by one.
ATTENTION ! Check that the new filters are within
the expiry date and that the packaging is
undamaged and sealed. Also check that the rubber
sealing in the thread of the unit is not damaged and
clean all the sealings.
pict. 2B :
Mount the new filters onto the blower unit one by
one. Screw all 3 filters tightly to prevent leaks.
Type of contaminant
Solid and liquid particles (Aerosols)
Organic gases and vapours with boiling point >65°C
Organic gases and vapours with boiling point >65°
Solid and liquid particles (Aerosols)
Organic gases and vapours with boiling point >65°
Inorganic gases and vapours such as Chlorine, hydrogen sulfid (H2S),
hydrogen cyanide (HCN)
Solid and liquid particles (Aerosols)
Organic gases and vapours with boiling point >65°
Inorganic gases and vapours such as Chlorine, hydrogen sulfid (H2S),
hydrogen cyanide (HCN),
sulphur dioxide (SO2)
ammonia (NH3)
Solid and liquid particles (Aerosols)
out, the green LED diode comes on at the
moment of trickle charging
- charger for CA CHEMICAL: both red
green LED diodes come on.
5. Disconnect the charger from the power supply.
Do not leave the charger in the power supply if
not in use !
6.2.2.

Battery changing

CA BASIC 2000
see picture supplement no.3
pict. 3A :
Removing the battery: Take the blower unit in both
hands facing the rear side of battery towards you.
Open the battery latch with your thumb. The latch is
positioned in the middle of the battery. Push the
battery off the unit using your thumbs.
pict. 3B :
Fitting the battery: Hold the blower unit in the same
position as before. Put the battery on the rail and
push it back onto the unit until the latch locks it in
the correct positon.