2.5
Inputs
START (button with N.O. contact or remote control) - the
•
START pulse starts the automation (opening or closing) on the
basis of the current state and the operating logic settings.
Note: The movement will take place at REDUCED SPEED
(safe operation) if the limit switches are not correctly
triggered following restarting after: power supply blackout
when the beam was not fully closed, or barrier blocked and
moved by hand because of power failure.
STOP button (button with N.C. contact) - the STOP input
•
stops the beam immediately. A START pulse is required to
continue movement. The STOP input has priority over all
other functions at all times.
Closing photocells - these photocells are only enabled
•
on the closing stroke. When triggered they will stop the
movement and immediately start the opening stroke.
These photocells will prevent closing as long as they are
covered.
Auxiliary safety with safety edge or photocell -
•
The detection of any obstacle will cause the response
programmed in the logic settings (see table).
Flashing light - this indicates the automation status as
•
follows:
•
OFF
automation stopped.
•
ON, fl ashing
automation operation.
ON, fast fl ashing
automation requires maintenance.
•
•
ON, fi xed
automation stopped with STOP, either during
operation after detection of obstacle or during EMERGENCY
MODE operation with batteries following a power supply
failure.
Warning light - this is a remote signal indicating the
•
current status of the automation:
•
OFF
automation closed.
•
ON, fl ashing
automation performing closing stroke.
•
ON, fi xed
automation open, performing opening stroke
or operating in the EMERGENCY MODE with batteries
following a power supply failure.
2.6
Test display: barrier and input status
The status of the barrier and the inputs can be displayed at
any time (see fi gure).
To switch on the display, press the
1 -
once quickly.
To switch off the display, press the
2 -
once quickly.
PTR-24
A
b
C
d
e
f
C i
H
I
L
M
N
R
S
T
U
V
fi gure 3 -
YELLOW button
YELLOW button
fi gure 4 -
- 23 -
CONTROL UNIT
Display 1
1
2
3
4
a
8 8
8
STOPPED
AUXILIARY SAFETY INTERVENTION
CLOSING PHOTOCELL INTERVENTION
CLOSED
OPEN
OPENING
CLOSING
OBSTACLE DETECTED
PRESLOWING ON CLOSING
PRESLOWING ON OPENING
SLOWING ON CLOSING
SLOWING ON OPENING
APPROACHING TO STROKE
REVERSING caused by an OBSTACLE
PREFLASHING ON OPENING
PREFLASHING ON CLOSING
ERROR (travel not completed within 20 sec.)
Barrier state : Display 1
Display 2
1
2
3
4
8
8
8
8
RADIO START
Display 2:
8
ON = Enabled
OFF = Disabled
STOP
ON = Disabled
OFF = Enabled
START
ON = Enabled
OFF = Disabled
AUXILIARY SAFETY
ON = Enabled
OFF = Disabled
Input state: Display 2
PHOTOCELL
ON = Disabled
OFF = Enabled
CLOSE
ON = Enabled
OFF = Disabled
PEDESTRIAN
START
ON = Enabled
OFF = Disabled