INSTALLATION
Specification
Wall mounting bracket
30 - 50 l
80 - 200 l
15.2 Wiring diagram
1
2
L
N
1 Terminal
2 High limit safety cut-out
3 Temperature controller
4 ON/OFF indicator
5 Heating element
6 Electrical resistance 560 ohm
7 Anode
8 Cylinder
15.3 Details on energy consumption
Product data complies with EU regulations relating to the Directive
on the ecodesign of energy related products (ErP).
Manufacturer
Load profile
Energy efficiency category
Energy conversion efficiency
%
Daily power consumption
kWh
Annual power consumption
kWh
Default temperature setting
°C
Sound power level
dB(A)
Off-peak periods possible
24
| PSH Trend
184
265
300
360
265
300
350
360
415
450
3
4
5
8
7
6
PSH 30 Trend PSH 50 Trend PSH 80 Trend PSH 100 Trend PSH 120 Trend PSH 150 Trend
232080
232081
STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON
S
M
C
34
37
2,591
6,451
544
1386
60
60
15
15
No
No
15.4 Heat-up diagrams
The heat-up time depends on the cylinder capacity, cold water
inlet temperature and heating output.
Graph assumes 15 °C cold water inlet temperature:
6
5
4
3
2
1
0
35
X Temperature setting [°C]
Y Heat-up time [h]
1 150 l
2 200 l
3 120 l
4 100 l
5 80 l
6 50 l
7 30 l
15.5 Fault conditions
In the event of a fault, temperatures of up to 95 °C at 0.6 MPa
can occur.
232082
232083
M
C
C
36
6,603
12,583
1412
2716
60
15
No
45
55
65
232084
232085
L
L
C
C
38
38
12,622
12,861
2723
60
60
15
15
No
No
www.stiebel-eltron.com
1
2
3
4
5
6
7
75
PSH 200
Trend
232086
L
XL
C
D
37
37
20,861
2763
4491
60
60
15
15
No
No