Beninca CP.ZED230-E Manual De Instrucciones página 14

Ocultar thumbs Ver también para CP.ZED230-E:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software
release.
uSE oF PRoGRAmmiNG KEYS
Press <PG> key to gain access to the Main Menu. These keys can be selected by pressing # and $ keys.
• If <#> is pressed, the Function Menu can be scrolled from top to bottom.
• If <$> is pressed, the Function Menu can be scrolled from bottom to top.
• If <PG> key is pressed, presetting to be modified can be entered.
• The preset values can be modified by using <#> and <$> keys.
• The value is programmed if <PG> key is pressed again. The word "PRG" appears on the display.
See paragraph "Programming Example".
NoTES:
Simultaneously pressing <#> and <$> from inside a function menu allows you to return to the previous menu without making any
changes.
If the push-button <$> is pressed with display off, this is like giving a step-by-step control.
When the board is switched on, the software version is displayed for around 5 sec
Hold down the <#> key or the <$> key to accelerate the increase/decrease of the values.
After waiting 60s the control unit quits programming mode and switches off the display.
In the tables hereunder the single functions available in the control unit are shown.
mENu
Automatic closure time. It is activated only with "TCA"=ON logic.
TCA
At the end of the preset time, the control unit controls a closure operation.
Motor operating time. The total stroke time in the motor opening and closing phases
is adjusted.
TM
With the ENC:ON logics, this value is automatically preset by the parameter self-
adjustment procedure (AUTO).
The space covered by the dooe leaf during braking in the closing phase is adjusted.
Braking in the opening phase is automatically preset at 1/4 of the closing space.
Tsm
0 = braking is disabled.
With ENC:OFF logics the value is expressed in seconds. Braking after the triggering of
the limit switch is adjusted.
PMo
The torque applied to the motor in the opening phase is adjusted.*
PMC
The torque applied to the motor in the closing phase is adjusted *.
Pso
The torque applied to the motor during braking in the closing phase is adjusted.*
Psc
The torque applied to the motor during braking in the opening phase is adjusted *
The activation time of the service light is adjusted.
With parameter :0, the area light function is activated. The light is switched on when
TLS
the motor is moving and during the TCA dwell time. The light switches off when the
motor stops.
The triggering threshold of the anti-crash device (Encoder) during the normal speed
SEAV
phase.*
99: maximum sensitivity - 0: minimum sensitivity
The triggering threshold of the anti-crash device (Encoder) during braking.*
SEAR
99: maximum sensitivity - 0: minimum sensitivity
The operating mode of the auxiliary output to terminals 19/20 is preset. See wire con-
nections in figure 2.
0: output configurated as SCA (open gate indicator light): Off with closed door, on
with open door, slow flash during opening, rapid flash during closing.
AUX
1: output configurated as radio channel II integrated receiver.
2: output configurated as PHOT TEST (photocell test).
3: output configurated as flashing light.
4: output configurated as service light additional to the light on the geared motor. Its
activation time is adjusted by TLS parameter.
14
PARAmETERS, LoGiCS ANd SPECiAL FuNCTioNS
PARAMETERS (PAR)
FuNCTioN
An incorrect setting of these parameters may cause danger.
Please comply with regulations in force!
* WARNiNG:
mEmo
miN-mAX-(default)
1-240-(40s)
2-180-(60s)
0-99-(10%)
1-99-(40%)
1-99-(40%)
1-99-(40%)
1-99-(40%)
0-240-(60s)
0-99-(0%)
0-99-(0%)
0-4-(0)
Tabla de contenido
loading

Tabla de contenido