Qualified Staff; Operation After A Shut Down; Replacement Interval; Disposal - Vizion HRS-100 Manual De Instalación Y Operación

Sistema de filtro para la optimización de aqua otable
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

NOTE!
f The non return valve is approved according DIN EN 13959 and affixed in the filter head
f Devices with boilers or water tanks such as coffee machines, etc... have to be cleaned, rinsed
and sanitized before operating the filter system to ensure the protection.
f In general for immunocompromised people and for babies it is recommended to boil the water
before use. This should be done for filtered and unfiltered water.
f For the protection against microbiological growth the filter contains a small amount of silver
(„bacteriostatic").* Therefore, there might be a harmless release of silver in concentrations below
the recommendations of the World Health Organisation (WHO). The term "bacteriostatic"
indicates that the system limits the passage or growth of bacteria that may already exist in the
incoming water.* It does not mean that the water leaving the system is safer to drink than the
water entering the system.
f Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system
5.2

Qualified Staff

Only authorized, instructed and specially trained personnel (professional plumber) are allowed to
install, start up and maintain the filter system
Authorized Personnel
 
Are to have the Instructions about the assigned tasks and possible risks in case of misuse
Professional
 
Professionals who are able to install, start up and maintain the filter system, because of their
training, experience and knowledge of applicable guidelines and codes
5.3

Operation after a Shut Down

The inlet valve (shut-off valve) has to be closed in case of a shut down.
 
If the shut down was more than two days (weekend, holiday....) the filter system has to be rinsed
 
with 1.1 – 1.3 gallons (4 – 5 liters) of water before use.
After a shut down period of more than 4 weeks the filter cartridge has to be replaced
 
5.4

Replacement Interval

The cartridge has to be replaced if:
f the capacity (see chapter 10) is reached
f at least every 12 months after installation
f if there was a shut down longer than 4 weeks
5.5

Disposal

Used filter cartridges, all other parts and the wrapping foil must be disposed according the local
rules. To protect the environment, recycling is recommended and appreciated.

6 Filter installation

6.1

Water Quality

The filter system must be operated with cold water fulfilling the legal requirements for drinking water.
I
WARNING!
Risks of misusage!
In any case of usage against the intended use e.g. poor water quality (not reaching the criteria for
drinking water) there is a risk of health.
* Not performance tested and certified by NSF
7
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Hrs-200

Tabla de contenido