Potentiometer Adjustment - Gerreka VIVO-M201(M) Guía Rápida De Instalación Y Programación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
DIP
Modes and functions
DIP1
DIP2
Advance warning
DIP3
Opening mode
Automatic or step-by-step mode
DIP4
(for pedestrian and total operation)
Reverse impulse /
DIP5
close impulse
Automatic mode optional
DIP6
(only if DIP4 = ON)
Maintaining hydraulic pressure
DIP7
(for hydraulic operators only)
Soft stop (only for operators
DIP8
without mechanical absorber)
Anti-crushing function (obstacle
detection); the obstacles are only
DIP9
detected when the gate has come
to a complete halt (only for
electromechanical actuators)
DIP10 No function
P1 P2 P3
P4 P5 P6
ST1
FT1
ST2
FT2
8
Function and mode selection using SW2 (DIP1 = OFF)
Option Effect
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF

Potentiometer adjustment

T.D (lapse between leaves): With the potentiometer set to the minimum
there is no delay time in opening or closing, i.e. the two leaves begin to open
at the same time and end up closing at the same time. With the potentiometer
set at more than the minimum, the delay time on the opening will be
approximately three seconds, and up to 20 seconds maximum on closing.
T.LG (garage light time): if the garage lighting circuit has been connected to
the control board, regulate the time which the lights shall remain on using T.LG.
T.E. (gate open standby time): if automatic functioning mode has been
programmed (DIP4=ON), set T.E. to adjust standby time with the gate open
(before automatic closing begins).
P.M (motor torque): use P.M. to adjust the maximum operator power value.
FCA2 COM FCC2
SCA
• Hydraulic operators: set P.M. at the maximum value.
• Electromechanical Actuators (anti-crushing function sensitivity): set P.M at the
minimum value possible, compatible with the proper operation of the gate.
P15 P14 P16
P7 P8
P11 P12
P22
Adjust the torque to respect the maximum closing thrusts set out in
24Va
LOCK
FCA1
FCC1
STOP
Standard EN12453:2000. Make the measurements as described in
P176M
Standard EN 12445:2000.
the flashing light comes on and the operation begins after a 3 second
warning
the flashing light comes on and the operation begins immediately
step-by-step opening (the gate halts if a key device is enabled during
opening, and closes if enabled again)
collective opening (the control board does not obey the key commands
during opening)
automatic mode (the gate closes automatically after standby time has
passed, which is adjusted using T.E.). Standby time restarts if the
photocell is enabled.
step-by-step mode (the gate only closes when receiving the key
command)
recede impulse enabled. If soft stop is selected (DIP8=ON), a close
impulse is also carried out
close and recede impulse disabled
during standby, the gate obeys the key commands (can be closed before
standby time finishes)
the gate cannot be closed until standby time finishes; a key command will
cause standby time to restart
Every two hours the system sends a close signal to the two leaves in
order to maintain hydraulic pressure
maintain pressure disabled
the leaves reduce their speed before reaching the stopper
the leaves reach the stopper at high speed
Function activated: during quick travel, the gate detects obstacles upon
collision and recedes (when soft stop is activated, DIP8 = ON) or remains
shut down (when soft stop is disabled, DIP8 = OFF) in order to prevent
crushing. NOTE: detection works during closing or opening at high speed
Function disabled
place always in OFF