This control board is factory set to use a two-channel receiver (e.g. IRRE2). This factory setting is modified if an RSD receiver is used and a
permanent code is recorded (decoding through the board, DIP1 + DIP4 or DIP6 = ON). To recover the factory settings, insert the IRRE2 card
and place DIP1 + DIP4 or DIP6 = ON. Then return the DIPs to their previous position.
Total opening radio code programming (with RSD receiver only)
If a receiver other than RSD is used, see
the corresponding instructions.
1 Connect the electrical power supply
and close the leaves, keeping PUL1 pressed
down.
2 Select the code in the transmitter.
If a single operator is used (A1), the three strokes of ST1 corresponding to step 6 must be carried
out quickly in order to keep the corresponding A2 times to a minimum. Similarly, the three strokes
of ST1 corresponding to steps 7, 8 and 9 must be carried out quickly.
1 Connect the electrical power
supply and close the leaves,
keeping PUL1 pressed down.
2 Place DIP1 in ON, DIP2 in ON,
DIP5 in ON (only with electrolock),
DIP8 in ON (soft stop)*.
S176B
DL3 lights up (programming
enabled).
3 Press ST1 to start opening
leaf 1.
*: If hydraulic operators with absorbers are used, soft stop is carried out mechanically by the operator (DIP8 = OFF)
This is carried out in the same way as total open/close
programming, with the following differences:
Using radio cards
3 Place the DIPs as shown in the figure
(DIP1=ON, DIP4=ON). DL3 lights up to
show programming mode enabled.
4 Press the button of the required
channel.
DL2
programming is complete.

Total open/close programming

4 Press ST1 to start soft stop
(with DIP8=ON only).
5 Press ST1 to finish opening.
6 Carry
out
the
same
sequence with leaf 2.

Pedestrian open/close programming

5 Place DIP1 and DIP4 in OFF.
DL3 remains off.
R176B
6 Disconnect
electrical power supply.
flashes
to
show
Programming is carried out in the same
way, using DIP6 instead of DIP4.
7 Press ST1 to start closing
leaf 2
8 Press ST1 to start soft stop
(with DIP8=ON only).
9 Press ST1 to finish closing.
• DIP1 and DIP3 are used instead of DIP1 and DIP2
• Carried out only with leaf 1
• ST2 is used instead of ST1
R176K
and
reconnect
Pedestrian opening radio
code
10
Carry
out
the
sequence with leaf 1.
11 Place DIP1 and DIP2 in OFF.
DL3 remains off.
the
same
S176K
7