Operation; Warning - Pinnacle Protemp PT-45-KFA Manual De Usario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Fueling The Heater:
Kerosene (K-1)
For optimal performance of this heater, it is strongly
suggested that K-1 kerosene be used, especially in
temperatures lower than 26°F (-3°C). K-1 kerosene
has been refined to virtually eliminate contaminants,
such as sulfur, which can cause a rotten egg odor
during the operation of the heater. Using diesel fuel
can cause excess soot production. Do not use Bio-
Diesel as this fuel will damage your heater's seals
and filter.
- CSA certified for use with K-1 kerosene, no. 1 &
no. 2 diesel, JP8/Jet A Fuel, no. 1 and no. 2 fuel oil.
DO NOT use any fuel that is not approved above.
DANGER
OR OPERATING. FIRE OR EXPLOSION COULD
RESULT.
CAUTION
FILL THE TANK OUTDOORS. BE SURE THAT
THE HEATER IS ON LEVEL GROUND WHEN
FUELING, AND NEVER OVERFILL THE TANK.

WARNING

- NEVER use fuel such as, benzene, alcohol, white glass,
camp stove fuel, paint thinners, or other oil
compounds in this heater. THESE ARE VOLATILE FUELS
THAT CAN CAUSE A FIRE OR EXPLOSION.
- NEVER store kerosene in the living space. Kerosene
should be stored in a well ventilated area outside the
living area.
- NEVER store kerosene in direct sunlight or near a source
of heat.
- NEVER use kerosene that has been stored from one
season to the next. Kerosene deteriorates over time.
OLD KEROSENE WILL NOT BURN PROPERLY IN THIS
HEATER.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
®

OPERATION

NEVER REFUEL
THIS HEATER
WHILE IT IS HOT
NEVER FILL THE
FUEL TANK IN-
DOORS. ALWAYS
DO NOT USE GASO-
LINE OR CRANK-
CASE DRAININGS.
NOTE: Kerosene should only be stored in a blue
container that is clearly marked "Kerosene." Never
store kerosene in a red container. Red is associated
with gasoline.
DANGER
CARBON MONOXIDE POISONING MAY LEAD TO
DEATH!
Ventilation:
- Risk of indoor air pollution and Carbon Monoxide
Poisoning. Use heater only in well ventilated
areas.
- Refer to Safety Information on page 3 for information
about Carbon Monoxide Poisoning.
- ALWAYS provide a fresh air opening in the heated space
of at least three square feet (2,800 sq. cm) for each
100,000 Btu / Hr. (29 kW) of heater output. Provide a
larger opening if more heaters are being used.
Minimum Ventilation Opening Needed
45-KFA
1.4 ft.²
1250 cm²
Minimum Ventilation Opening Needed
175T-KFA
5.3 ft.²
4930 cm²
6
Kerosene Forced Air Heater User's Manual
80T-KFA
140T-KFA
2.4 ft.²
4.2 ft.²
2230 cm²
3902 cm²
215T-KFA
6.5 ft.²
5990 cm²
Tabla de contenido
loading

Este manual también es adecuado para:

Pt-80t-kfaPt-140t-kfaPt-175t-kfaPt-215t-kfa

Tabla de contenido