Controller operation
Code
Name
37
DISCHARGE T°
38
OUT COIL T°
39
T° W A
40
T° W B
41
T° W C
42
T° W 1
43
T° W 2
44
DS SETPT W
45
SETPOINT W1
46
SETPOINT W2
47
COOL IN Z1
48
COOL IN Z2
49
FORCED MODE
50
CDU ASK MODE
51
CDU MODE
52
DEF MODULE
53
DEF CDU
MAX COMP
54
FREQ
55
REQUEST FREQ
56
REAL FREQ
COMP
57
RUNTIME
FLOW SW
58
MODE
CONEX
59
NUMBER
60
DS NUMBER
61
CA NUMBER
62
CDU CAPACITY Size of the CDU connected to the hydronic module
NO TERMINAL/
63
3 WAY VALVE/
DIRECT
NO TERMINAL/
64
3 WAY VALVE/
DIRECT
65
CONEX IN Z1
ROOM SENS
66
Z2
OP. OUT
67
RANGE
Gb.indd 13
Gb.indd 13
Description
Compressor discharge T° value measured by the CDU
sensor
Outdoor coil T° value measured by the CDU sensor
Value of the water T° entering in heat exchanger
T° of water measured by sensor TWB
T° of water exiting heat exchanger
T° of water directed to terminal zone 1
T° of water directed to terminal zone 2
Main water setpoint
Setpoint for the water directed to terminal zone 1
Setpoint for the water directed to terminal zone 2
Allows for cooling in terminal zone 1
Allows for cooling in terminal zone 2
Alllows to force the system in a specifi c operating mode:
standby (standby), booster heat (heating at maximum
frequency) booster cool (cooling at maximum frequency)
Operating mode requested by the hydronic module:
heating (heating), booster heating (heating at maximum
frequency), cooling (cooling), booster cooling (cooling
at maximum frequency), reduced heating (heating at
reduced frequency), reduced coooling (cooling)
Actual CDU operating mode
Display of the faults of the module
Display of the faults of the CDU
Maximum compressor frequency
Compressor frequency requested by the hydronic
module
Actual CDU compressor frequency
Number of hours the compressor has been running
since the beginning
State of the fl ow switch depending of the waterfl ow
in the system
User interface software versione
PCB2 board software version (see electrical scheme)
PCB1 board software version (see electrical scheme)
Type of zone kit connected to zone 1: nothing
connected (NO TERMINAL), kit with 3 way valve (3 WAY
VALVE), direck kit (DIRECT)
Type of zone kit connected to zone 2: nothing
connected (NO TERMINAL), kit with 3 way valve (3 WAY
VALVE), direct kit (DIRECT)
Presence of user interface in terminal zone 1
Presence of room temperature sensor in terminal
zone 2
Operating outside allowed range
Possibility
Min Max
Factory
READING
READING
READING
READING
READING
READING
READING
READING
READING
READING
YES / no
no
YES / no
no
no/Stb/b_h
no
/b_c
OFF/Stb/h/
b_h/c/b_c/
READING
r_h/r_c
OFF/Stb/h/
b_h/c/b_c/
READING
r_h/r_c
READING
READING
READING
READING
READING
READING
READING
READING
READING
READING
5 / 6.5 / 10
READING
/ 12.5
NO
TERMINAL=0
NO
3 WAY
TERMINAL
VALVE=1
DIRECT=2
NO
TERMINAL=0
NO
3 WAY
TERMINAL
VALVE=1
DIRECT=2
YES / no
YES
YES / no
no
YES / no
READING
80AW1-80AW2
Unit
°C
°C
°C
°C
°C
°C
°C
°C
Hz
Hz
Hz
hours
kW
13
1-01-1970 1:21:12
1-01-1970 1:21:12