Skirt Panel Installation (Skirted Models Only); Troubleshooting Procedures - Jacuzzi PRIMÓ Manual De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Skirt Panel Installation (Skirted models only)

To remove the skirt panel -
Grasp an edge of the skirt panel and pull to separate.
To reinstall the skirt panel (Figure 17) -
Align the six (6) posts on the panel with the six (6) receptor sockets on the
tub and press into place.
Skirt Panel Adjustment (Figure 18) -
Insert a standard screwdriver into the receptor socket, through the slot at
the rear. Turn clockwise to tighten and counter-clockwise to loosen.
Fig. 18
Receptor Socket
Slot
Exterior View

Troubleshooting Procedures

PROBLEM
Whirlpool - Pump/motor does not start
Whirlpool - Pump/motor operates but no fully
adjustable jets are functioning
Whirlpool - Pump/motor operates but air is not injected
into the water
Whirlpool - Water leakage from pump unions
Whirlpool - Pump/motor shuts off by itself before time
elapses
Water not maintaining temperature
Air Bath - Blower does not start
Air Bath - Blower operates but air is not exiting all of
the holes
Air Bath - Blower shuts off unexpectedly
If the unit is within the warranty period, contact Jacuzzi Luxury Bath Service Support at 1-800-288-4002 with your bath's serial number before work is started. The
NOTES
serial number is located on the Specification/Serial Number Plate (the plate is located behind the equipment area).
Page 12
Interior View
PROBABLE CAUSES
No power to pump/motor
Pump/motor not plugged in
Pump/motor faulty
Jets are closed
Suction cover/strainer may be clogged
Air valves are closed
Overtightened, O-ring may be pinched or improperly
seated, undertightened
Motor thermal protection has deactivated pump/motor
due to overheating (supply voltage low)
GFCI tripped
Inadequate supply wiring
High Limit switch on heater has been tripped
No power to blower
Blower not connected
Blower faulty
Obstructed air holes
20 minute timer has elapsed
GFCI tripped
Inadequate supply wiring
Improper ventilation
www.jacuzzi.com
Reset GFCI
Insert plug securely into outlet
Ensure the control panel is connected to control box
Contact Jacuzzi Luxury Bath @ 800-288-4002
Open jets by rotating counter-clockwise
With the motor turned OFF, remove the suction cover/
strainer and remove any debris. Replace the suction
cover before operating
Open air control valves
Loosen unions , check and reseat O-ring. If O-ring has
been pinched out of shape, replace (refer to number
below). When tightening union nuts, handtighten only.
Let motor cool; thermal protection will reset. Check for
proper ventilation (check supply voltage)
Reset GFCI. If it continues to trip, do not use this unit.
Disconnect the unit and have the problem corrected by
a licensed electrician before using.
Consult a licensed electrician to correct the wiring unit.
Press Reset button on heater
Reset GFCI and/or breaker
Ensure plug is fully in outlet
Ensure control panel is connected to control box
Ensure control box is connected to control panel
Contact Jacuzzi Luxury Bath @ 800-288-4002
Remove debris with a toothpick or tooth brush
Turn on blower
Reset GFCI. If it continues, to trip, do not use the unit
Consult a licensed electrician to correct
Contact Jacuzzi Luxury Bath @ 800-288-4002
Primó™ Collection
Primó™ Collection
Fig. 17
Receptor Socket
Post
REMEDY
Installation and Operation