Troubleshooting - Master TENTEvent125 Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

WARNING: Never service heater while it is plugged in, connected
to propane supply, operating, or hot. Severe burns and electrical
shock can occur.
ObSERVED FAULT
Fan. does. not. turn. when.
switch(s).1.or.2.are.pressed.
to.ON
Heater.will.not.ignite
120193-01A

TroUBLeSHooTing

POSSIbLE CAUSE
1..No.electrical.power.to.heater
2..Thermostat.set.too.low
3..Ambient. temperature. is. too.
high.. Thermostat. is. satis-
fied
4..Defective.motor
1..User. did. not. follow. installa-
tion.or.operation.instructions.
properly
2..No. spark. at. ignitor.. To. test.
for.spark,.follow.step.5.under.
Replacing Ignitor,.page.15..If.
you.see.spark.at.ignitor,.have.
heater serviced by qualified
service. person.. If. no. spark.
seen:
. A). Loose. or. disconnected.
ignitor.wire
B) Wrong spark gap
C) Bad ignitor electrode
D) Bad spark DSI
3..Air.proving.switch.blocked
www.desatech.com
REMEDY
1..Check. voltage. to. electrical.
outlet.. If. voltage. is. good,.
check.heater.power.cord.for.
breaks
2..Adjust. thermostat. to. higher.
setting
3..Wait.for.ambient.temperature.
to.decrease
4..Replace.motor..See.Motor and
Blower Assembly,.page.13
1..Repeat. installation. and. op-
eration. instructions.. See.
Installation,. page. 10. and.
Operation,.page.11
2.
. A).Check.ignitor.wire..Tighten.
or.reattach.loose.ignitor.wire.
B) Assure gap between ignitor
electrode.and.burner.deck.is.
0.13"/0.15".(3.3/3.8.mm)..Do.
not.bend.electrode..Doing.so.
may.cause.it.to.break
. C). Replace. ignitor. elec-
trode.. See. Replacing Ig-
nitor,.page.15
. D). Replace. spark. trans-
former..See.Replacing DSI
Control,.page.15
3..Clean.tubing
17
Tabla de contenido

Solución de problemas

loading

Productos relacionados para Master TENTEvent125 Serie

Este manual también es adecuado para:

Tentevent125 tb116Tentevent125 tb117Tentevent125 tb118

Tabla de contenido