Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Installation Instructions
Check with your state and local public works department
for plumbing and sanitation codes. You must follow these
guidelines as you install the Household Water Filtration Housing.
Using a qualified installer is recommended.
Be sure the water supply conforms with the Specifications
Guidelines. If the water supply conditions are unknown,
contact your municipal water company.
This Household Water Filtration System must be properly installed and located in accordance with the Installation Instructions before it is used.
Check with your local public works department for plumbing
codes. You must follow their guides as you install the Household
Water Filtration System.
Use the Household Water Filtration System on a potable, safe-
to-drink, home COLD water supply only. The filter cartridge will
not purify water or make unsafe water safe to drink.
Protect the Household Water Filtration System and piping from
freezing. Water freezing in the housing will damage it.
Your Household Water Filtration System will withstand up to 125
psi water pressure. If your house water supply pressure is higher
than 80 psi during the day (it may reach higher levels at night),
install a pressure-reducing valve before the housing is installed.
REQUIRED TOOLS AND ACCESSORIES
FOR INSTALLATION
2 wrenches: 1
and 1
1 8
1 4
Pipe cutter
Ruler or tape measure
Cordless drill and a 3/16 drill bit (optional)
File
Emery paper
Screwdriver
The FXUSC (Rev. 2) filter is tested and
certified by NSF International against
NSF/ANSI Standard 42 for materials
requirement only.
COMPONENT
SAFETY PRECAUTIONS
PROPER INSTALLATION
(2)
compression adapters with ferrule
3 4
and nut (compatible to home plumbing)
UL-approved grounding clamps and
6-gauge grounding wire
Teflon tape
If unit is to be installed on plastic,
PVC or galvanized plumbing, separate
hardware must be purchased.
This GXWH04F is tested and certified
by NSF International against NSF/ANSI
Standard 42 for materials and structural
integrity requirements only.
49-50202-3 (
GEAppliances.com
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
Household Water Filtration System*
WARNING:
microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
It is highly recommended that a water shut-off valve be placed
directly upstream of your household filter.
Do not install on HOT WATER. The temperature of the water
supply to the Household Filtration System must be between the
minimum of 40°F and the maximum of 100°F. See the Specification
Guidelines.
Do not install the Household Water Filtration System using copper
solder fittings. The heat from the soldering process will damage the
unit. If making a soldered copper installation, do all sweat soldering
before connecting pipes to the housing. Torch heat will damage
plastic parts.
WARNING:
material after installation. Small parts remaining after installation
could be a choke hazard.
Do not install filter in an outside location or anywhere it will be
exposed to sunlight.
COMPONENT
10-12 GE)
GXWH04F and GXWH20S
Do not use with water that is
Discard all unused parts and packaging
CONTENTS INCLUDED WITH PRODUCT
Filter housing and head
Product literature
Sediment filter FXUSC (Rev. 2)
(for GXWH20S only)
Housing wrench
Mounting bracket with (2) screws
Timer and batteries
The GXWH20S system using FXUSC (Rev.
2) filter is tested and certified by NSF
International against NSF/ANSI Standard
42 for reduction of particulate Class V.
The GXWH20S has been tested and
Certified by WQA according to CSA
B483.1.
Tabla de contenido
loading

Resumen de contenidos para GE GXWH04F

  • Página 1 Timer and batteries Screwdriver The FXUSC (Rev. 2) filter is tested and This GXWH04F is tested and certified The GXWH20S system using FXUSC (Rev. certified by NSF International against by NSF International against NSF/ANSI 2) filter is tested and certified by NSF...
  • Página 2: About The Filter Cartridge

    Filter Cartridge Replacement You should change your filter when the water flow is noticeably reduced or at least every 3 months. 1 Turn off water to filter. For model GXWH04F, water 7 Slowly rotate control handle to the FILTER position must be shut off from an upstream valve.
  • Página 3: Installation Overview

    Failure to maintain this ground path distance “D” on the pipe. D is about 5 for GXWH04F model and may result in an electric shock hazard. If the cold water pipe is used for GXWH20S model.
  • Página 4 5 Open any downstream faucet and allow filter and housing to 3 Check entire system for leaks. flush for 30 minutes (120 gallons) (model GXWH20S) or 15 minutes (60 gallons) (model GXWH04F). Timer Installation and Application Instructions Timer battery installation and change...
  • Página 5: Parts List

    PARTS LIST Ref. No. Part No. Part Description WHTIMER Timer WS03X10038 O-Ring WX5X140 Housing Wrench 49-50202-3 Installation Instructions To obtain replacement parts, call toll-free 800.626.2002 (U.S.), LIMITED ONE-YEAR WARRANTY What does this warranty cover? How do I make a warranty claim? of the “Proof of Purchase.”...
  • Página 6: Système De Filtration D'eau

    Tournevis Le filtre FXUSC (Rev.2) est testé et certifié par Ce GXWH04F a été essayé et certifié par Le système GXWH20s utilisant un filtre FXUSC (Rev. 2), a NSF International conformément à la norme NSF International conformément aux été...
  • Página 7: La Cartouche De Filtration

    On doit changer la cartouche de filtration lorsque le débit d’eau diminue sensiblement, et au moins à intervalles de trois mois. Fermer l’arrivée d’eau au filtre. Pour le modèle GXWH04F, on doit fermer le Lors de la première installation du système, ouvrez tous les robinets en aval robinet d’arrêt en amont.
  • Página 8: Étapes De L'installation

    Le défaut de maintenir ce trajet de mise à la terre peut entraîner un 13,3 cm (5 po) pour le modèle GXWH04F et à 14,6 cm (5 po) pour le risque d’électrocution. Si la canalisation d’eau froide est utilisée pour la mise modèle GXWH20S.
  • Página 9: Installation Du Filtre

    Placez les attaches en bronze sur la tuyauterie en cuivre. Serrez les vis. ou en métal galvanisé pour effectuer une liaison à la terre des prises électriques de la maison. Cette mise à la masse vous protège contre les Fixez le fil sur les attaches comme indiqué. Serrez les vis.
  • Página 10: Liste Des Pièces

    État ou le procureur général de votre État. Contactez nous sur ge.com, ou appelez le numéro sans frais 800.952.5039 aux États-Unis. Au Canada, contactez nous sur www.electromenagersge.ca, ou appelez le numéro sans frais 866.777.7627.
  • Página 11: Precauciones De Seguridad

    INSTRUCCIONES DE INSTALACION Sistema de filtración de agua para el hogar GXWH04F and GXWH20S PRECAUCIONES DE SEGURIDAD ADVERTENCIA: Consulte con su departamento de obras públicas local y estatal para los No use con agua que no sea segura a nivel códigos de plomería y sanidad.
  • Página 12: Los Cartuchos Del Filtro

    Botón rojo Cronómetro para reducir la disponible a través del departamento de Partes y Servicio presión de GE llamando al 1.800.626.2002, número de parte Manija Botón rojo WS60S10005). Cerciórese de que el aro tórico está en de control para reducir la la ranura.
  • Página 13 No mantener esta 13,3 cm (5 ”) para el modelo GXWH04F y 4,6 cm (5 ”)para el modelo GXWH20S.
  • Página 14: Instalación De La Unidad

    Lentamente abra el paso del agua. Revise todo el sistema para que no hayan goteras. 15 minutos (modelo GXWH04F). Instalación del cronómetro e instrucciones de reinicio Instalación del cronómetro nstalación y cambio de las baterías del cronómetro...
  • Página 15: Lista De Partes

    Attorney General en su localidad. Póngase en contacto con nosotros en ge.com, o llame sin cargo al 800.952.5039, o 866.777.7627 en Canada.
  • Página 16 Notes...

Este manual también es adecuado para:

Gxwh20s

Tabla de contenido