10 Attachment
• After connecting the wires to the terminal block, lightly pull on the wires to make sure that
they do not come out of the terminals.
• Do not let strain on the wiring cause damage. Use a strain relief near the wiring to release the
tension. Refer to
Figure 10.4
A - Cable clamp
Scre
Screw
w
Shape
Gauge
Size
M3
M4
≤ 25 mm
(AWG 10)
*1
M5
≥ 30 mm
(AWG 8)
M6
(WAF: 5 mm)
*1
When you wire drive models 2042, 2056, 4031, 4038, 4044, and 4060, select the correct tools for the wire gauge.
*2
Use 6.35 mm (0.25 in) bit socket holder.
*3
Use a torque wrench that can apply this torque measurement range.
270
Figure 10.3 Tightening Slotted Screws
for example.
Figure 10.4 Strain Relief Example
Table 10.1 Recommended Wiring Tools
Wire
Adapter
Model
SF-BIT-SL
-
Bit
0,5X3,0-70
SF-BIT-SL
-
Bit
1,0X4,0-70
2
SF-BIT-SL
Bit
1,2X6,5-70
2
SF-BIT-HEX 5-
-
Bit
YASKAWA TOMPC71061753A YASKAWA AC Drive GA500 Installation and Operation Instruction
WWW.NNC.IR
Bit
Manufacturer
PHOENIX
CONTACT
PHOENIX
CONTACT
PHOENIX
CONTACT
PHOENIX
50
CONTACT
Torque Driver
Torque
Model
Wrench
(Tightening
(Tightening
Torque)
Torque)
TSD-M 1,2NM
-
(0.3 - 1.2 N∙m)
TSD-M 3NM
-
(1.2 - 3.0 N∙m)
TSD-M 3NM
-
(1.2 - 3.0 N∙m)
4.1 - 4.5 N∙m
-
*3
-
5 - 9 N∙m
*2
*2 *3