Rheem 2450 Serie Manual De Operación E Instalación página 27

Tabla de contenido
Función
Mayor/
menor
voltaje
Voltaje
Temp. serpentín
Temp
Ambiental
Temp.
Succión
Temp EXV
Temo. Sat
Temp. Agua
Installer Menu
Operación
bombeo
Calor
bombeo
Operación
en válvula
Válvula de retorno
posición 1
Válvula de succión
Posición 1
Modo Aux
Rango
Ver solo – VAC
Ver solo -
gradis F o C
Ver solo–
grados F o C
Ver solo –
grados F o C
Ver solo –
grados F o C
Ver solo –
grados F o C
Ver solo –
grados F o C
Si o no
Velocidad 4
deshabilitada, variable
habilitada,
Deshabilitada
deshabilitada
Habilitada,
Deshabilitada
Deshabilitada
Piscina/Spa
Piscina
Piscina/Spa
Piscina
AUX APAG., SALIDA AUX ,
SALIDA REMOTA, SALIDA
APAGADO
CALOR
27
Nivel de
Acceso
Press UP or DOWN buttons to access
Instalación/
additional temperature measurements.
Mantenimiento
Instalación/
---
Mantenimiento
Instalación/
Mantenimiento
Instalación/
Mantenimiento
Instalación/
Mantenimiento
Instalación/
Mantenimiento
utilized when the pressure transducer
Instalación/
Mantenimiento
displayed whenever EXV is enabled.
Instalación/
Mantenimiento
No
Instalación/
Mantenimiento
Sub-menú
Instalación/
Mantenimiento
Sub-menú
Instalación/
Mantenimiento
Sub-menú
Instalación/
AUX
Mantenimiento
Sub-menú
Descripción
Displays the 24VAC voltage as
measured by the control board.
Displays the coil temperature
sensor value – used for defrost
operation.
Displays the ambient
temperature sensor value – used
for Outside Lockout operation
and defrost.
Displays the suction line temperature
sensor value – used for EXV
operation ONLY. Will not be shown if
EXV Disabled is selected.
Displays the EXV temperature
sensor value – ONLY available with
EXV Enabled AND EXV Temp
Sensor utilized. NOTE: This is ONLY
is NOT used.
Displays the pressure transducer
converted to a temperature. It is
Displays the water temperature
sensor value – used for
temperature operation
Select YES and press the MENU
button to gain access to additional
programming selections in this
Installer/Service Sub-menu. Select
No and the next MENU button
press returns to the Set Current
Time screen.
If pump control through the HPPH is
desired, select the appropriate pump
mode – 4-Speed Enabled for
discrete speed control or Variable
Enabled for PWM control of pump.
This feature selects the Digital input
(pump speed) for the pump to
operate during HPPH operation.
This feature allows control of 3-way
valves. Disabled is the default.
When Enabled, the control will seek
information as to whether the Return
and Suction valves should be
positions for Pool or Spa positions
for each pump period.
See description of auxiliary
mode operation on page 30.