Beretta 30 B.S.I. Manual De Instalacion Y Uso página 11

Ocultar thumbs Ver también para 30 B.S.I.:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
Switching on
Switch on the boiler as follows:
- access the gas tap through the slots in the cover located in the
lower part of the boiler
- open the gas tap by turning it anti-clockwise (fig. 15)
- power the boiler.
15
Each time the power supply is switched on the boiler carries out
an automatic venting cycle that lasts about 2 minutes. The display
reads "SF" (fig. 16) and the "function selectors"
sequence. Press the
venting cycle.
If the check is concluded correctly, once the automatic venting
cycle has been completed the boiler is ready to work.
16
The boiler turns on in the status it was in before it was switched
off: if the boiler was in the winter mode when it was switched
off, it will turn on again in the winter mode. If it was in the OFF
mode, the display will show two segments in the central area
(fig. 17). Press the
button to enable operation.
17
Choose the desired operating mode by pressing
until the
symbol moves to:
WINTER
SUMMER
WINTER function (fig. 18)
With the selector in this position, the boiler provides hot water for
the heating and provides water to the water tank to allow domestic
hot water preparation. Function S.A.R.A is enabled in this position
(see chapter "Boiler functions").
18
SUMMER function (fig. 19)
With the selector in this position, the boiler provides water to the
water tank with a temperature stabiliser to allow domestic hot water
preparation.
open
position
light up in
button to interrupt the automatic
19
Adjusting heating water temperature
Turning the selector A (fig. 20), after having positioned the selector
mode on winter
temperature.
A
20
Turn clockwise to increase the temperature and anticlockwise to
decrease. The bar segments light up (every 5°C) as the tempera-
ture is increased. The selected temperature value appears on the
display.
Adjusting heating water temperature with an external sensor
connected
When an external probe is connected, the value of the delivery
temperature is automatically chosen by the system which rapidly
adjusts ambient temperature to the changes in external tempera-
ture. Just the central segment of the bar is illuminated (fig. 21).
To increase or decrease the temperature with respect to the value
automatically calculated by the electronic board, turn the heating
water selector clockwise to increase and anticlockwise to decrease.
The bar segments light up (at every comfort level), correction
tolerance lies between - 5 and + 5 comfort levels (fig. 21). When
choosing the level of comfort, the digit area of the display shows
the required level of comfort while the bar shows the matching
segment (fig. 22).
°C
button,
+ 4/5
+ 3
+ 2
+ 1
0
- 1
- 2
- 3
- 4/5
21
22
Adjusting domestic hot water temperature
To adjust domestic hot water temperature storaged in the water
tank, turn switch B (fig. 23) clockwise to increase and anticlockwise
to decrease. The bar segments light up (every 3°C) as the tempe-
rature is increased.
The selected temperature value appears on the display.
When choosing the temperature, both for heating and domestic
hot water, the display shows the value being selected. About 4
seconds after the selection has been made, the modification is
memorised and the display returns to the delivery temperature
read by the probe.
, it is possible to regulate the heating water
ENGLISH
ENGLISH
ENGLISH
ENGLISH
ENGLISH
1 1
1 1
1 1
1 1
1 1
Tabla de contenido
loading

Tabla de contenido