Saeco DEU 001 Manual De Instalación Y De Uso página 22

Deshumidificador de ambiente transferible
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
22
PROBLEM
The dehumidifier fails to
It is not properly plugged in.
run
The water tank is full
The
collection tank is incorrectly
inserted.
The
dehumidification has been
reached
The ON/OFF button has
not been pressed (Mirage,
Mirage Combi, Mirage
Plus)
The seat of the floater has
not
completely.
I n a d e q u a t e
The set dehumidification
Dehumidification
degree has been reached
The air filters are obstructed
Low air speed (Mirage,
Mirage Combi, Mirage
Plus)
There is no air flow
The
obstructed
The fan does not work *
(Mirage S).
The equipment is running
The
without dehumidifying
obstructed
The temperature and/or
humidity in the room is too
low
The room is too large*
The Combi or Heating
The safety protection relay
mode has been selected
for the heating element has
but the equipment fails to
tripped
heat the room (Mirage
Combi).
The temperature selected
has been reached
The room is too large*
The room humidity is lower
The display shows
than 30% or higher than
(Mirage Plus).
80%
(*) These causes do not mean that there is a fault with the unit.
To correct problems that have not been described in the table and/or if the solutions advised fail to resolve the problem,
contact an authorised service center.
TROUBLESHOOTING
POSSIBLE CAUSE
Make sure the plug is securely in the outlet.
Empty the condensation collection tank and put it back in the unit.
condensation
Insert the condensation collection tank correctly.
set
degree
of
Increase the desired degree of dehumidification using the appropriate
knob
Press the ON/OFF button.
Empty again the can by overturning it completely.
been
emptied
Increase the degree of dehumidification desired using the appropriate
knob
Clean and/or replace the filters
Increase the air speed
air
filters
are
Clean and/or replace the filters
Increase the degree of dehumidification desired using the appropriate
knob until the led is on; then await the technical starting time.
air
filters
are
Clean and/or replace the filters
It is sometimes normal that the equipment fails to dehumidify in certain
surrounding conditions (see "running limits" table)
To restore normal running conditions unplug unit for 2 minutes, locate
and eliminate the cause of the overheating then plug the unit back in.
If the maximum temperature is desired but has not been selected, the
Heating mode may be restarted by selecting a higher temperature.
TROUBLESHOOTING
SOLUTION