TIP 5: FENCE CONNECTION
1. Underground lines should only be installed with Art. 32611/32612. (Installation in
the protective pipe is recommended).
2. Above‑ground lines should be protected from sharp edges. If possible, lay in
insulators to prevent flashovers.
3. Fence supply lines should only be laid with high voltage resistant cables. No house
installation cables may be used (approval only up to 500V).
TIP 6: IMPROVE GROUNDING
1. Drive the earth rods into damp soil at least 1 m deep and 10 m away from the
building.
2. If necessary, add more rods at a distance of at least 3 m between them and
connect them together. Earth rods must be non‑rusting, which means they are
either stainless steel or galvanised.
TIP 7: TYPICAL LAYOUT OF AN ELECTRIC FENCE SYSTEM
3
2
1. ENERGISER
It supplies power to the fence system. The choice of a unit depends on the total fence
length, animal species to be fenced in or out and available power supply options. There
are 9 V battery energisers, 12V rechargeable battery energisers and mains energisers.